IBM Support

PN78188: TELNET SERVER DOESN'T CORRECTLY HANDLE THE READ PARTITION QUERY LIST (X'FF 03').

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer is tring to telnet HOST/MVS from a SUN w/s :
    TELNET command is issued, user is asked for the terminal type,
    he enters VT100 value, but at this point the session is never
    established, he never obtains the main application menu related
    to the appl defined in the DEFAULTAPPL statement.
    The problem is that the READ PARTITION Query List (x'FF 03')
    is not correctly handle and TELNET server rejects it with the
    36002 sense which means 'The length is too long or too short
    in the READ PARTITION field. The error occurred in the WRITE
    STRUCTURED FIELD command'.
    READ PARTITION Query (x'FF 02') is correctly handled.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All telnet user's with applications that     *
    *                 send READ PARTITION Query List (x'FF 03')    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Customer is tring to telnet HOST/MVS    *
    *                      from a SUN w/s.  TELNET command is      *
    *                      issued, user is asked for the terminal  *
    *                      type, he enters VT100 value.            *
    *                      At this point the session is never      *
    *                      established, he never obtains           *
    *                      the main application menu related       *
    *                      to the appl defined in the              *
    *                      DEFAULTAPPL statement.                  *
    *                                                              *
    *                      The problem is that the DEFAULTAPPL is  *
    *                      sending a READ PARTITION Query List     *
    *                      (x'FF 03') and the TELNET server        *
    *                      rejects it with the 36002 sense, which  *
    *                      means length error.                     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    TND3270 (WSForder) was checking the length of the
    READ PARTITION and was assuming the length to be = 5.
    This is true for a READ PARTITION QUERY, but not for a
    READ PARTITION QUERY LIST.
    

Problem conclusion

  • TND3270 (WSForder) will now only check for the length = 5 if
    this is a READ PARTITION QUERY.  If it's a READ PARTITION QUERY
    LIST, the length is not checked.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PN78188

  • Reported component name

    TCP/IP V3 MVS

  • Reported component ID

    5655HAL00

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1995-11-15

  • Closed date

    1996-01-12

  • Last modified date

    1996-03-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UN86440

Modules/Macros

  • EZAJT327
    

Fix information

  • Fixed component name

    TCP/IP V3 MVS

  • Fixed component ID

    5655HAL00

Applicable component levels

  • R310 PSY UN86440

       UP96/02/06 P F602

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCY4DZ","label":"DO NOT USE"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: