IBM Support

Security Bulletin: IBM WebSphere DataPower XC10 is vulnerable to a buffer overflow in the Command Line Interface (CLI) that may affect system availability. (CVE-2016-2870)

Created by Michael Stuy on
Published URL:
https://www.ibm.com/support/pages/node/278887
278887

Security Bulletin


Summary

IBM WebSphere DataPower XC10 is vulnerable to a buffer overflow in the Command Line Interface (CLI) that may affect system availability.

Vulnerability Details

CVEID: CVE-2016-2870
DESCRIPTION:
IBM WebSphere DataPower XC10 is vulnerable to a buffer overflow in the Command Line Interface (CLI) that may affect system availability.
CVSS Base Score: 2.7
CVSS Temporal Score: See https://exchange.xforce.ibmcloud.com/vulnerabilities/112800 for the current score
CVSS Environmental Score*: Undefined
CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L)

Affected Products and Versions

WebSphere DataPower XC10 Appliance Version 2.1
WebSphere DataPower XC10 Appliance Version 2.5

Remediation/Fixes

Apply an interim fix, according to the table below. Interim fixes are associated with the original APAR that is documented in the table. Because these APAR references might be updated to more recent APARs, see the links in the table for the most recent interim fix information.

This interim fix contains a new default SSL certificate, as the previous default SSL certificate, which was never intended for production use, has an MD5 signature and is no longer compatible with Java. For deployments that have not installed XC10 interim fixes since February 26, 2016, the following applies: installing this interim fix will make it incompatible with any WebSphere Datapower XC10 appliances that are running with an MD5 certificate, including the default SSL certificate that was shipped prior to this interim fix. If the appliance is configured with a custom keystore and certificate with an MD5 signature, it must be replaced prior to upgrading to this interim fix or the 'clear-tls-config' command must be run on the appliance before or after performing the upgrade. Failing to do so will result in the appliance failing to start. Note that changing the active certificate for an appliance collective does require that the cache be reloaded and client truststores must be configured to trust the new certificate.

ProductVersionAPARLink to interim fix
WebSphere DataPower XC10 Appliance V2.1 on appliance 9235-92X2.1IT14815Refer to the Version 2.1 table in Recommended fixes for WebSphere DataPower XC10 Appliance.
WebSphere DataPower XC10 Appliance V2.1 on appliance 7199-92X2.1IT14815Refer to the Version 2.1 table in Recommended fixes for WebSphere DataPower XC10 Appliance.
WebSphere DataPower XC10 Appliance V2.5 on appliance 7199-92X
Version 2.5

Important
: See More information link and follow instructions to determine if you have an old or newer SSD driver on your appliance using the show ssd-version command.
IT14815Refer to the Version 2.5 table in Recommended fixes for WebSphere DataPower XC10 Appliance.
WebSphere DataPower XC10 Appliance V2.5 virtual image2.5IT14815Refer to the Version 2.5 table in Recommended fixes for WebSphere DataPower XC10 Appliance.

Workarounds and Mitigations

There is no workaround. The interim fix must be applied to correct the problem.

Get Notified about Future Security Bulletins

References

Off

Change History

27 May 2016: Original version published.

*The CVSS Environment Score is customer environment specific and will ultimately impact the Overall CVSS Score. Customers can evaluate the impact of this vulnerability in their environments by accessing the links in the Reference section of this Security Bulletin.

Disclaimer

Review the IBM security bulletin disclaimer and definitions regarding your responsibilities for assessing potential impact of security vulnerabilities to your environment.

[{"Product":{"code":"SSS8GR","label":"WebSphere DataPower XC10 Appliance"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"General","Platform":[{"code":"PF009","label":"Firmware"}],"Version":"2.5;2.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]