IBM Support

PM99382: ADD NEW OPTIONS TO CERTAIN IMSPA REPORTS AND SOME ADDITIONAL NEWFUNCTION CHANGES AS SHOWN IN THE LIST BELOW

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • The following is a list of new function changes being added:
    1. Add option to IMS PA Gap Analysis report to ignore x'6D'
       records.
    2. Add optional precision to form-based Summary report for COUNT
       type fields when averaged.
    3. Amend ALTSCHED processing for IMS Monitor reports.
    4. Update Fast Path Region Occupancy report for IMS V13 to use
       x'5904' records in deriving times.
    
    Additional IMS V13 related issue being addressed:
    ABEND0C7 in IPIGDISP + 1568 when producing BMP Checkpoint report
    in IMS V13.1.  This ABENDS0C7 occurs because the date formatting
    routine called from the IMS PA BMP Checkpoint report is
    expecting to be passed a valid UTC date derived from the
    IMS x'47' record, but under IMS V13.1 incorrect data may be
    passed.                                                     S0C7
    
    Another symptom of the above issue:
    ABEND0C4 IPISBMPC at x'18D8' on TM instruction due to R3
    pointing to unavailable storage.                  ABENDS0C4 S0C4
    
    Additional symptoms corrected: 1) Loop in IPI4PROC ranging
    between instructions at about x'7DE' to x'956'.    LOOPS LOOPING
    2) ABEND0C4 IPIIPROC near x'584E' which is x'102' after label
    REC37.                                            ABENDS0C4 S0C4
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Performance Analyzer V4.3       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Add new options to certain IMSPA        *
    *                      reports as well as some additional      *
    *                      new function changes                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The following issues are addressed by this APAR:
    1. Add option to IMS PA Gap Analysis report to ignore x'6D'
       records.
    2. Add optional precision to form-based Summary report for COUNT
       type fields when averaged.
    3. Amend ALTSCHED processing for IMS Monitor reports.
    4. Update Fast Path Region Occupancy report for IMS V13 to use
       x'5904' records in deriving times.
    5. Abend S0C7 running BMP Checkpoint report in IMS v13.1
    

Problem conclusion

Temporary fix

Comments

  • The following changes have been made for the above issues:
    1. Gap Analysis report has option to exclude x'6D' records from
       processing as they may distort the report results.
       Default is to include x'6D' records.
    2. Optional precision for form-based Summary reports when
       averaging COUNT fields, 0-2 decimal places. Default is 0 if
       not specified.
    3. IMS Monitor Global Option "Override 'IWAIT for no-message'"
       (ALTSCHED) processing changed, see ++HOLD doc for
       explanation.
    4. Fast Path Region Occupancy report updated for IMS V13 to use
       x'5904' records in calculating report times,
       report layout changed with the  inclusion of additional
       columns.
    5. Correct handling of IMS V13 x'47' records in BMP Checkpoint
       report.
    6. Form-based reports and Extract for LOG dialog panels changed
       to insert PROGRAM as selection criteria, see ++HOLD doc for
       for explanation.
    7. IMS PA IRUR report for RACF statistics and Dispatcher
       statistics updated to correct values for certain time fields.
    8. Sundry dialog updates
    

APAR Information

  • APAR number

    PM99382

  • Reported component name

    IMS PERF ANALYZ

  • Reported component ID

    5655E1500

  • Reported release

    430

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2013-10-17

  • Closed date

    2013-11-07

  • Last modified date

    2014-07-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI12279

Modules/Macros

  • IPI#DDLI IPI#FROI IPI#GP6D IPI#RPRE IPI#RPRS IPIAQR11 IPIARPT1
    IPIATRND IPICANAL IPICNACK IPICPORT IPICPROC IPICSCAN IPICTLOG
    IPICTPIP IPICTRAC IPICTREX IPICXCAR IPICXCPT IPIFCHEK IPIFCOMD
    IPIFOCMD IPIFPROC IPIFTCMD IPIGGET  IPIIPROC IPILINFO IPIOINFL
    IPIOPROC IPIOTRAC IPIPBXA1 IPIPBXB1 IPIPBXC1 IPIPBXD1 IPIPBX91
    IPIPCFLT IPIPMPA1 IPIPMPB1 IPIPMPC1 IPIPMPD1 IPIPMP91 IPIPXATF
    IPIPXCAX IPIRFCMD IPIRSBC  IPIRSC   IPIRSC1  IPIRSC1P IPIRSC4
    IPIRSC8  IPIRSDEC IPIRSGP  IPIRSL4  IPIRSL4B IPIRSL4D IPIRSMC
    IPIRSSAV IPIRSS4  IPIRSS4B IPIRSS4D IPIRST3P IPIRSX4A IPISAPAR
    IPISBMPC IPISCOMD IPISCSAR IPISDAPI IPISDASH IPISFPDC IPISFPEM
    IPISFPIR IPISFPRO IPISFPTR IPISIRUR IPISLINI IPISLOG  IPISLOGD
    IPISLOGH IPISLOGM IPISLOGP IPISLOGS IPISLOGT IPISLOGX IPISMERG
    IPISRESP IPISXCAR IPITDMGR IPITPROC IPI4DMGR IPI4PROC IPI4QMGR
    

Fix information

  • Fixed component name

    IMS PERF ANALYZ

  • Fixed component ID

    5655E1500

Applicable component levels

  • R430 PSY UI12279

       UP13/11/14 P F311  

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Performance Analyzer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"430"}]

Document Information

Modified date:
03 October 2020