  • Attributes that should be editable in the AWAY Database (where
    the ReqIF file is imported) remain Locked ? cannot be edited.
    
    
    Steps to reproduce:
    -----------------------
    1.? Create a Module M1 and create a new Attribute (say Text) A1
    
    2.? Add the newly created Attribute to the Standard View of the
    Module and save it as a new View say V1.
    
    3.? Create another View in the Module which contains only one
    column corresponding to the newly created Attribute A1. Name it
    as V2.
    
    4.? Create a new ReqIF Definition by using the Module M1, Lock
    Attributes, select V1 in Include
    data in View and select V2 as Apply locks to view.
    
    5.? Export this ReqIF Definition to ReqIF format.
    
    6.? Import the ReqIF file in an AWAY database OR you can import
    the same into any other new DOORS Project of the existing DB.
    
    7.? You would observe in the newly created Module (created from
    Importing the ReqIF file) the attribute A1 is not editable.
    
    Workaround:
    ---------------
    Instead of exporting the definition as ReqIF format, export it
    as RIF format.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users affected                                           *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Attributes that should be editable in the AWAY Database      *
    * (where the ReqIF file is imported) remain Locked & cannot be *
    * edited.                                                      *
    *                                                              *
    * Steps to reproduce: -----------------------                  *
    * 1.> Create a Module M1 and create a new Attribute A1 (say    *
    * type Text)                                                   *
    * 2.> Add the newly created Attribute to the Standard View of  *
    * the Module and save it as a new View say V1.                 *
    * 3.> Create another View in the Module which contains only    *
    * one column corresponding to the newly created Attribute A1.  *
    * Name it as V2.                                               *
    * 4.> Create a new ReqIF Definition by using the Module M1,    *
    * Lock Attributes, select V1 in Include data in View and       *
    * select V2 as Apply locks to view.                            *
    * 5.> Export this ReqIF Definition to ReqIF format.            *
    * 6.> Import the ReqIF file in an AWAY database OR you can     *
    * import the same into any other new DOORS Project of the      *
    * existing DB.                                                 *
    * 7.> You would observe in the newly created Module (created   *
    * from Importing the ReqIF file) the attribute A1 is not       *
    * editable.                                                    *
    *                                                              *
    * If the same set of steps are performed and the ReqIF         *
    * Definition is exported as RIF format, the attribute A1 is    *
    * indeed available for editing in the AWAY Database. Hence,    *
    * the issue is seen only when the definition is exported as    *
    * ReqIF format.                                                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This is a client side fix
    

Problem conclusion

  • The code has been changed so that the issue no longer occurs.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM97796

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    950

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-09-25

  • Closed date

    2014-06-07

  • Last modified date

    2014-06-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R960 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYQBZ","label":"Rational DOORS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.5","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
02 November 2021