  • Closed as program error.

Error description

  • Headline:
    Duplicate and missing test script execution entries in the test
    suite execution results
    
    Abstract:
    Executing Test Suite execution steps in a non-chronological
    order causes some missing execution results whereas others
    appear multiple times in the Test Suite execution results.
    
    Error Description:
    To reproduce the issue :
    - create a test case and associate 12 test scripts to it
    - create a test suite and associate 12 times that same test case
    to it.
    - edit the test suite to change the default test script for each
    of the attached test case entry to have :
    Test suite -?
    TC -? test script 1
    TC -? test script 2
    TC -? test script 3
    TC -? test script 4
    TC -? test script 5
    TC -? test script 6
    TC -? test script 7
    TC -? test script 8
    TC -? test script 9
    TC -? test script 10
    TC -? test script 11
    TC -? test script 12
    - execute the test suite in parallel using the following order:
    execute test script 1, 2, 3, 4, 5, 6, skip 7 and 8, execute 9 10
    11 then execute 7 and 8.
    - looking at the test suite result : 7 and 12 are missing from
    the results and 9 and 10 are listed twice.
    
    WORKAROUND:
    The workaround is to execute the steps in chronological order
    from 1 till 12.
    

Local fix

Problem summary

  • Duplicate and missing test script execution entries in the test
    suite execution results
    

Problem conclusion

  • Fixed in 4.0.4
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM94188

  • Reported component name

    RATL QUALITY MG

  • Reported component ID

    5724V1000

  • Reported release

    402

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-07-31

  • Closed date

    2013-09-24

  • Last modified date

    2013-09-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL QUALITY MG

  • Fixed component ID

    5724V1000

Applicable component levels

  • R404 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSR27Q","label":"Rational Quality Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]