IBM Support

PM92184: A HANG OCCURS DURING DEPLOYMENT REQUIRING THAT THE SERVER BE RESTARTED TO RECOVER.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A hang occurs during deployment requiring that the server be
    restarted to recover.
    

Local fix

  • Server restart.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All administrators of a Worklight server.                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The Worklight server does not recover if the database server *
    * is restarted.  This problem will cause deployment and        *
    * un-deployment of applications and adapters to fail. If the   *
    * database that was restarted is also the reports database,    *
    * and if the Worklight server uses reports, every action that  *
    * is logged in the Worklight server reports will fail (login,  *
    * logout, invoke procedure, etc.).                             *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * -                                                            *
    ****************************************************************
    The problem occurred because the code that creates the db locks
    did not make sure that unlock is called if an error occurs.
    

Problem conclusion

  • The code was fixed so that the unlock occurs even if there is an
    error interacting with the database.
    
    The fix for this APAR is currently targeted for fixpack 5.0.6.2
    and is available in fixpack 6.0.0.1.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM92184

  • Reported component name

    WORKLIGHT ENTER

  • Reported component ID

    5725I4300

  • Reported release

    506

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-07-01

  • Closed date

    2013-09-19

  • Last modified date

    2013-09-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WORKLIGHT ENTER

  • Fixed component ID

    5725I4300

Applicable component levels

  • R506 PSY

       UP

  • R600 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"506","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]