A fix is available
APAR status
Closed as program error.
Error description
Miscellaneous bug fixes.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Fault Analyzer Version 10 users. * **************************************************************** * PROBLEM DESCRIPTION: 01. IBM Fault Analyzer IDI0095W * * Unexpected condition IDIDODSN:360 * * when exiting interactive analysis * * of an MVS dump. * * APAR PM95334 * * 02. IDI0095W Unexpected condition found * * in IDISUPDI:1426: IDISUPDI:1851 * * :1426 dup time precedes * * fault entry. * * APAR PM95335 * * 03. Listing exit issues IDISF messages * * when exit returns a SYSDEBUG dsn. * * APAR PM95336 * * 04. After scrolling Fault Entry List * * display right, abend code * * explanation is shown instead of * * processing line command. * * APAR PM95337 * * 05. COBOL ODO table has incorrect * * stride. * * APAR PM95338 * * 06. Language Environment heap analysis * * errors not indicated in the * * Synopsis section of the report. * * APAR PM95339 * * 07. Fault Analyzer's CICS SDUMP * * "SM ECDSA Subpool Summary" panel * * displays some incorrect or unclear * * values, * * APAR PM95340 * * 08. Lock flag incorrectly reset after * * fault entry interactive reanalysis * * when Enter is pressed on exit to * * save changes to user data. * * APAR PM95341 * * 09. Loop during abend analysis leading * * to IDI0005S message. * * APAR PM95342 * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 01. When completing an interactive reanalysis of an MVS SVC or SYSMDUMP, the write minidump process might issue IDI0095W from IDIDODSN:360. 02. IBM Fault Analyzer CICS fast duplicate processing might record a vendor altered start time rather than the wall-clock time, even when the UseIDISTime option is set. 03. Listing exit fails to process a SYSDEBUG, then attempts to process it as a compiler listing. 04. When a point-and-shoot field, such as the "Abend" column field, is scrolled to logically overlap with the line command field, then the point-and-shoot field is incorrectly processed instead of the line command. 05. ODO recalibration includes redefinitions which causes data item length to be added again. 06. The specific Language Environment heap analysis errors found in this case had not been made eligible for identification in the report Synopsis. 07. Some values are being obtained from the wrong place. Some values are correct but are displayed in hex, while the CICS VerbExit displays them in decimal. 08. The fault entry lock flag was being managed, both in the fault entry member, and in the history file cache, causing incorrect updates. 09. FA code was not allowing for an LE CIB next pointer to be pointing to itself. Hence, FA went into a loop which eventually exhaused all storage and gave a IDI0005S message.
Problem conclusion
01. The logic has been changed to handle the allocation condition. 02. Code updated to accommodate date/time alteration test products in the CICS fast duplicate recording process. 03. Listing exit now correctly processes SYSDEBUG files. 04. An error determining the line offset in displays with a non-scrollable section on the left has been fixed. 05. Only the original definition is inlcuded in recalibration of ODO tables. 06. All Language Environment heap analysis errors are now being identified in the Synopsis with a reference to detailed information about the errors in the Language Environment heap analysis section of the report. 07. Fault Analyzer has been changed to display the correct values, and to display both hex and decimal values where appropriate. 08. The fault entry lock flag is now only being managed in the history file cache. 09. Loop detection code added.
Temporary fix
Comments
APAR Information
APAR number
PM91557
Reported component name
FAULT ANALYZER
Reported component ID
5655V5100
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-06-20
Closed date
2013-08-22
Last modified date
2013-09-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK96964
Modules/Macros
HADQA10J IDICALOC IDICASUB IDICCFND IDICOPYR IDICRXDX IDICRXEI IDICRXET IDICRXHC IDICSMF IDICSPC IDICUX ***This field was truncated. To obtain the full apar record, please contact your local support center.***
Fix information
Fixed component name
FAULT ANALYZER
Fixed component ID
5655V5100
Applicable component levels
RA10 PSY UK96964
UP13/08/28 P F308
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: