PM87142: BPA CRD BATCH JOB ABEND. BPOMAXA0 - ERROR ISSUE COMMAND FPEM0518E NONZERO IFI RETURN CODE. RC 8, REASON X'00E60820'

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • BPA CRD Batch Job Abend.
    When BPA CRD job start in sampling mode, it attempts to reuse
    the same OPx buffer. If other DB2 monitoring activities are
    using the same buffer, the folowing abend may occur.
    .
    BPOMAXA0 - Error Issue Command
    FPEM0518E Nonzero IFI return code. RC 8, REASON X'00E60820'
    DSNW184I  +DB2P OP BUFFER OP3 NOT AVAILABLE
    DSN9023I  +DB2P DSNWVCM1 '-START TRACE' ABNORMAL COMPLETION
    FPEM0818E An error occurred starting the DB2 traces above
    FPEM0518E Nonzero IFI return code. RC 8, REASON X'00E60820'
    DSNW137I  +DB2P SPECIFIED TRACE NOT ACTIVE
    DSN9022I  +DB2P DSNWVCM1 '-STOP TRACE' NORMAL COMPLETION
    

Local fix

  • Apply PTF when available
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - BPA - Buffer Pool Analyzer (Host part)     *
    ****************************************************************
    * PROBLEM DESCRIPTION: BPA CRD job may complete prematurely    *
    *                      with DSNW184I, DSN9023I, FPEM0818E and  *
    *                      FPEM0518E messages when it has been     *
    *                      started in sampling mode.               *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    Premature BPA CRD job termination may be encountered if job has
    been started in sampling mode but other monitor occupied OPn
    buffer chosen by the BPA CRD job. That happened because BPA CRD
    task attempted to hold the same OPn buffer for several data
    collection sessions in sampling mode.
    
    PROBLEM CONCLUSION:
    Code changed to use first available OPn buffer for every new
    BPA CRD data collection session.
    
    KEYWORDS:
    BPA CRD TERMINATION DSNW184I DSN9023I FPEM0818E
    

Problem conclusion

  • PROBLEM CONCLUSION:
    Code changed to use first available OPn buffer for every new
    BPA CRD data collection session.
    
    KEYWORDS:
    BPA CRD TERMINATION DSNW184I DSN9023I FPEM0818E
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM87142

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-04-16

  • Closed date

    2013-08-02

  • Last modified date

    2017-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK96384 UK96385

Modules/Macros

  •    BPOMAB02 BPOMAXA0
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R510 PSY UK96384

       UP13/08/06 P F308

  • R511 PSY UK96385