APAR status
Closed as program error.
Error description
Disabling compression for catalog server communication in a large scale topology can prevent the LockTimeoutExceptions and allow complete server start up of the catalog service domain.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: WebSphere eXtreme Scale users that * * are running servers * * in WebSphere Application Server with * * a large scale environment. * **************************************************************** * PROBLEM DESCRIPTION: LockTimeoutException exceptions occur * * during the * * startup of the catalog service domain * * in a large scale environment. * **************************************************************** * RECOMMENDATION: * **************************************************************** In a large topology enivronment running WebSphere eXtreme Scale inside of WebSphere Application server, the catalog service domain might not start all of the container servers successfully. LockTimeoutException exceptions can occur in the first failure data capture (FFDC) log files.
Problem conclusion
The APAR fixes the LockTimeoutException exception on the catalog server so that the catalog service domain can start successfully.
Temporary fix
Comments
APAR Information
APAR number
PM79506
Reported component name
WS EXTREME SCAL
Reported component ID
5724X6702
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-12-19
Closed date
2013-01-31
Last modified date
2013-01-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WS EXTREME SCAL
Fixed component ID
5724X6702
Applicable component levels
R850 PSY
UP
R860 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSTVLU","label":"WebSphere eXtreme Scale"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]