Performing an action results in the error 'CRMUD0082E Execution of a hook failed' with 'CRMCU0088E The string passed in to Perl is not a valid string' in Rational ClearQuest Web

Troubleshooting


Problem

Attempts to run an action results in the following error using IBM Rational ClearQuest Web client. Error from RPC server: Problem creating resource: CRMUD0082E Execution of a hook failed during the action . It was the ACTION_INITIALIZATION hook attached to the Task "". The reason for the failure was: CRMCU0088E The string passed in to Perl is not a valid string in the current code page/locale, "UNIX client". The string is "????". *AFTER Attempts to perform an action results in the error 'CRMUD0082E Execution of a hook failed' with 'CRMCU0088E The string passed in to Perl is not a valid string' when using IBM Rational ClearQuest Web client.

Symptom

The full error message is similar to the following.

The full error message is as follows:

Error from RPC server: Problem creating resource: CRMUD0082E Execution of a hook failed during the action <action_name>. It was the ACTION_INITIALIZATION hook attached to the Task "<record_id>". The reason for the failure was:
CRMCU0088E The string passed in to Perl is not a valid string in the current code page/locale, "UNIX client". The string is "????".
The following characters are invalid:
U+767b at 1
U+9332 at 2
U+3059 at 3
U+308b at 4

> Details
CRVSV0078E Error from RPC server: CRVSV0744E Problem creating resource: CRMUD0082E Execution of a hook failed during the action <action_name>. It was the ACTION_INITIALIZATION hook attached to the Task "<record_id>". The reason for the failure was: CRMCU0088E The string passed in to Perl is not a valid string in the current code page/locale, "UNIX client". The string is "????". The following characters are invalid: U+767b at 1 U+9332 at 2 U+3059 at 3 U+308b at 4

[{"Product":{"code":"SSSH5A","label":"Rational ClearQuest"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Component":"CM Server","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"8.0","Edition":"","Line of Business":{"code":"LOB77","label":"Automation Platform"}}]

Log InLog in to view more of this document

This document has the abstract of a technical article that is available to authorized users once you have logged on. Please use Log in button above to access the full document. After log in, if you do not have the right authorization for this document, there will be instructions on what to do next.

Document Information

Modified date:
29 September 2018

UID

swg21883629