IBM Support

PQ49389: LOGON TO IMS FAILED WITH EMS1333E / EMS1334E WITH VT=YES.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • logon to IMS failed with msgEMS1333E / msgEMS1334E with VT=yes.
    A relay mode session is set up to IMS application with VT=Y,
    mod3 terminal type and requested logmode ext32783.
    IMS determines that the alternate screen size is larger then the
    primary and changes the bind to reflect that the primary screen
    size to be used is the same as the alternate screen size
    requested. IMS resetted the query bit.
    IMS send the first screen image as a alternate screen in
    an Erase Write Alternate. It includes a SBA x'115e40' = 25/01.
    NVAS changes 3270 WCC from the Erase Write Alernate x'7e' to
    an Erase Write  x'F5' and send the screen image to the physical
    terminal primary screen.
    This is rejected with sense 10050000 and EMS1333e.
    Reselecting IMS gets EMS1334e and after clear key IMS resend
    panel with x'7E' and now NVAS send it to the real terminal with
    x'7E' too and it works.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All NVAS users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: A relay mode session is set up to IMS   *
    *                      application with VT=Y, mod3 terminal    *
    *                      type and requested logmode ext32783.    *
    *                      Because of a wrong screen size user     *
    *                      the logon procedure is rejected         *
    *                      with sense 10050000 and EMS1333E        *
    *                      message. After reselecting the appl     *
    *                      EMS1334E message appears.               *
    ****************************************************************
    * RECOMMENDATION: APPLY THE PTF FIXING THIS APAR               *
    ****************************************************************
    A relay mode session is set up to IMS
    application with VT=Y, mod3 terminal
    type and requested logmode ext32783.
    IMS determines that the alternate
    screen size is larger than the primary
    and changes the bind to reflect that
    the primary screen size to be used is
    the same as the alternate screen size
    requested. IMS resetted the query bit.
    IMS send the first screen image as an alternate screen in
    an Erase Write Alternate.
    Real terminal has a primary screen size 24*80 and alternate
    size 32*80.
    IMS set primary = alternate screen size = 32*80.
    NVAS changes 3270 WCC from the Erase Write Alernate x'7e' to
    an Erase Write  x'F5' and send the screen image to the physical
    terminal primary screen.
    This is rejected with sense 10050000 and msg EMS1333E at users'
    screen.
    After reselecting the appl msg EMS1334E appears.
    ADDITIONAL SYMPTOMS:
    KEYWORDS: EMS1333E EMS1334E ext32783
    

Problem conclusion

  • A check has been added for the default and the alternate
    screen size.
    In the case they are different (both < or >) then it is setted
    to ON the bit in the ridt. If they are equal then this bit is
    left to OFF.
    This bit shows whether the primary screen size
    of the pseudo terminal relay session has been switched or
    changed.
    Then if this bit is setted to ON it has been notified that
    it has not to be changed the screen image from the EWA to EW.
    

Temporary fix

Comments

  • &#215;**** PE02/04/04 PTF IN ERROR. SEE APAR PQ59709  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PQ49389

  • Reported component name

    NVAS/ESA MVS 2.

  • Reported component ID

    569503601

  • Reported release

    111

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2001-06-07

  • Closed date

    2002-01-03

  • Last modified date

    2002-04-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ61534

Modules/Macros

  • EMSEVRS  EMSEWR10
    

Fix information

  • Fixed component name

    NVAS/ESA MVS 2.

  • Fixed component ID

    569503601

Applicable component levels

  • R111 PSY UQ61534

       UP02/02/01 P F201

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMX3","label":"Tivoli NetView Access Services"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"111","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
17 April 2002