IBM Support

PQ43453: EQQX139E VSAM I/O REQUEST FAILED. RETURN CODE: 8,REASON CODE: 12

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • EQQX139E VSAM I/O request failed. Return code: 8, Reason code:12
    and in the Controller MLOG:
    EQQN043E UNSUCCESSFUL VSAM I/O REQUEST.DETAIL INFORMATION FOLLOW
    EQQN043I ACTIVE TASK IS GS EXECUTOR 01  . Lmod IS EQQGSBEX
    EQQN043I I/O REQUEST IS FROM EQQGSGOP 98/05/14 13.54.23 AT +0178
    EQQN043I REQUESTED FUNCT IS GS ON LOGICAL FILE CP,DDN EQQCP1DS
    EQQN043I VSAM RETURN CODE IS 8, REASON CODE IS 0012, KEY IS 03
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: ALL OPC USERS,                               *
    *                 FUNCTION=MCP.                                *
    ****************************************************************
    * PROBLEM DESCRIPTION: EQQX139E VSAM I/O request failed,       *
    *                      Return code=8, Reason code=12.          *
    ****************************************************************
    * RECOMMENDATION: APPLY THE PTF FIXING THIS APAR               *
    ****************************************************************
    The following error message:
    'EQQX139E VSAM I/O request failed, Return code = 8, Reason
    code = 12' is displayed on the Ready List panel and the Ready
    List cannot be used for the current workstation.
    This problem was caused by an incorrect processing of the MCP
    option that allows you to rerun an occurrence.
    

Problem conclusion

  • This fix concerns an error related to an enhancement in OPC
    version 2.2 and 2.3. This enhancement modified the declaration
    of the fields occurrence number and operation number to obtain
    occurrence number > 32k and operation number > 99.
    Since the module EQQMCRER was not updated accordingly, we had
    to change some declarations in it to process correctly the
    rerun of an occurrence in the CP.
    After having applied this fix, you are allowed to enter the
    Ready List for the selected workstation with no error message
    displayed.
    202Y
    302Y
    EQQMCRER
    

Temporary fix

  • A temporary fix is now available.
    

Comments

  • A temporary fix is now available.
    

APAR Information

  • APAR number

    PQ43453

  • Reported component name

    TME 10 OPC V2 R

  • Reported component ID

    5697OPC01

  • Reported release

    200

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2000-11-16

  • Closed date

    2001-01-08

  • Last modified date

    2001-03-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ50100 UQ50101

Modules/Macros

  • EQQMCRER
    

Fix information

  • Fixed component name

    TME 10 OPC V2 R

  • Fixed component ID

    5697OPC01

Applicable component levels

  • R202 PSY UQ50100

       UP01/02/05 P F102 Ž

  • R302 PSY UQ50101

       UP01/02/05 P F102 Ž

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRULV","label":"IBM Workload Scheduler for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"200","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: