Error description
Each time a Verify and Synchronize is run, the 'tme' and 'dyntrk' attributes are automatically changed to "yes" and 'fc_err_recov' to "fast_fail" for all fibre channel adapters, including those not intended to be used for SAN Heartbeat.
Local fix
After the Synchronize, manually change the attributes for the desired adapters.
Problem summary
Each time a Verify and Synchronize is run, the 'tme' and 'dyntrk' attributes are automatically changed to "yes" and 'fc_err_recov' to "fast_fail" for all fibre channel adapters, including those not intended to be used for SAN Heartbeat.
Problem conclusion
Skip automatic setting interface's parameters for Sancomm. Customer has to manually set the required settings if they want to use the interfaces for Sancomm.
Temporary fix
Comments
APAR Information
APAR number
IV62142
Reported component name
POWERHA SYSMIR
Reported component ID
5765H3900
Reported release
713
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2014-07-01
Closed date
2014-07-08
Last modified date
2016-08-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
POWERHA SYSMIR
Fixed component ID
5765H3900
Applicable component levels
R713 PSY U868571
UP16/08/19 I 1000
PTF to Fileset Mapping
U864230 cluster.es.server.utils 7.1.3.2
U864230 cluster.es.server.utils 7.1.3.2
U864230 cluster.es.server.utils 7.1.3.2
U865785 cluster.es.server.utils 7.1.3.3
U865785 cluster.es.server.utils 7.1.3.3
U865785 cluster.es.server.utils 7.1.3.3
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
20 October 2021