APAR status
Closed as canceled.
Error description
PROBLEM 1: After defining a switch to HCD error msg's may be received when creating a production IODF. The procedure to correct the error situations are as follows: 1) CBDG065I MSGCBDG065I The switch control unit XXX of switch yy has no channel path attached via the switch. a) Using HCD on the Define Channel Path panel specify a dynamic switch, entry switch and port. On this panel the port specification refers to the entry port. Dyn + --Entry +-- / CHPID Type + Mode + Switch Switch Port Con. _ 20 CNC DED 01 01 C2 . 2) CBDG060I A switch and port must be specified for control unit xxxx to connect the control unit to channel path yy of processor bbbbb. a) In this case the switch and port information must be filled in using the Change Control Unit Definition Panel. Action code 'c' on the Control Unit List panel will take you to the Change Control Unit Definition panel. Connected to switches . . . 01 __ __ __ __ __ __ __ + Ports . . . . . . . . . . . D7 __ __ __ __ __ __ __ + . In this case the Port specification is the port to which the control unit will be attached. . **************************************************************** * For a more detailed description see the HCD and Dynamic I/O * * Reconfiguration Primer Chapter 5 (GG24-4037) * **************************************************************** PROBLEM 2: CBDA260I Device type 9032 not supported by os type MVS. MSGCBDG154I CBDG154I No switch information is available MSGCBDG150I CBDG150I No Switch Information Table (SIT) found for switch type The above messages are received when trying to define a d/t9033 or d/t9032 in HCD. Customers need to have FMID HSWF100 installed. This is the FMID for ESCON Director Device Support. For a 9033 model 3 (9033-3) OW08540 is required. This FMID is orderable as a feature of MVS. The Feature number is 5872. Note: In order to use the 9032 or 9033 it is not necessary to define the switch CU and IODEVICE in your IODF. Thus if the Escon Director Device support FMID is not installed devices that are attached to an ESCON director will be accessable via MVS even if the switch CU and IODEVICE are not defined at that time. However, the CHPID and Control Unit's must be modified in the IODF to include switch number and link address. Once the switch is defined in the IODF additional error reporting and validation will be available. See HCD Primer for additional information. PROBLEM3: CBDG149I-port range for installed ports outside range of supported ports. Error received when user tries to set the installed port range from C0-FB to 80-FB. UW21164 will add new port ranges. The user must be sure to select the correct switch type.
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
Info. apar.
APAR Information
APAR number
II08399
Reported component name
V2 LIB INFO ITE
Reported component ID
INFOV2LIB
Reported release
001
Status
CLOSED CAN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
1994-12-22
Closed date
1994-12-22
Last modified date
1998-05-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19N","label":"APARs - OS\/390 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
26 May 1998