APAR status
INTRAN
Error description
When an ESCON CTC SCTC device used for communications by VTAM does not come up online during MVS system initialization at IPL, any attempt to issue a VTAM VARY NET,ACT,ID=Linename involving that device, will fail with MSGIST380I ACTLINK 081C003C. The definition for SNA sense 081C003C indicates that the device has not been made available by the operating system. For the VTAM activate to succeed, the device must be VARY'd online using the MVS VARY online command. Once it is accessible, reissue the VTAM VARY NET,ACT command. CONFIGURATION explained: One of the two systems using the SCTC device has it attached via a CTC type chpid. The other system using the SCTC device has it attached via a CNC type chpid. Hereafter, these systems will be referred to as the CTC system and the CNC system, respectively. ______ ____ ______ | | CTC / \ CNC | | | SYSx |<-------->|SCTC|<-------->| SYSy | |______| chpid \____/ chpid |______| The SCTC will not come up online to the CNC system when the CTC system does not have a logical path established to the device. This condition will occur, for example, when the CTC system has done an I/O Interface Reset (but NOT a System Reset). An I/O Interface Reset would have occurred if a recovery action of F1 was selected from the SYSDEF frame and the system subsequently entered a disabled wait state. One common circumstance under which a system will enter a disabled wait state is when it is partitioned out of a SYSPLEX. Other conditions causing the SCTC to not come up online to the CNC system are: - The processor on the CTC side is powered off. - The CTC and CNC chpids attach to an ESCON director and either port is blocked, or the path within the director is prohibited. - The CTC chpid has been configured off from the system (hardware) console.
Local fix
If the CTC system is in a disabled wait state, system reset it or IPL it before IPL'ing the CNC system. If the CNC system has already been IPL'd but the SCTC device is offline to it, the device must be MVS VARY'd online in order for a VTAM VARY NET to be successful. It cannot be MVS VARY'd online with the CTC system still in the disabled wait state. Either system reset the CTC system or IPL it. --------------------------------------------------------------- --------------------------------------------------------------- -------- NOTE WELL!!! THIS PROBLEM IS RESOLVED ------------ -------- AT VTAM 4.3 FOR AHHC (APPN) USERS. ------------ --------------------------------------------------------------- ---------------------------------------------------------------
Problem summary
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
II08325
Reported component name
V2 LIB INFO ITE
Reported component ID
INFOV2LIB
Reported release
001
Status
INTRAN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
1994-11-16
Closed date
Last modified date
1996-01-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19N","label":"APARs - OS\/390 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
15 January 1996