Error description

  • 5746XX100 R160 RH57 RB59 RC59 DL/1 DL/I DLI.
    DIFFERENT LINKAGE ERROR MESSAGES DURING DL/I PTF INSTALLATION.
    SOME INFORMATION CAN BE FOUND IN COVER-LETTERS, SOME IN INFO-
    APARS BUT NEARLY COMPLETE DESCRIPTION OF ALL POSSIBLE ERROR-
    MESSAGES CAN BE FOUND IN 'PROGRAM INSTALLATION  DIRECTORY' WHICH
    CUSTOMERS MOSTLY CANNOT FIND AND EVEN SUPPORT CENTER PSR'S DON'T
    HAVE. FOR THAT REASON I'LL ENTER RELEVANT PART OF PROGRAM
    DIRECTORY. FURTHERMORE, NEVER FORGET TO ADD II02032 IF YOU SEND
    DL/I APARS.
    *
    IF YOU INTEND TO ASSEMBLE ANY OF THE DL/I MODULE SOURCE BOOKS
    FROM THE DL/I SOURCE LIBRARIES, CERTAIN ASSEMBLY ERROR OR
    WARNING MSG'S MAY RESULT. SUCH MSG'S DO NOT AFFECT THE ASSEMBLER
    OUTPUT IN ANY WAY. DESCRIBED BELOW ARE SOME YOU MAY ENCOUNTER:
    -    MSGIPK001 IPK001 END STATEMENT IN MACRO OR COPY CODE
    DELETE END CARD FROM DL/I SOURCE BOOK PRIOR ASSEMBLY. IF THE END
    CARD WHICH WAS REMOVED CONTAINS AN ENTRY POINT ADDRESS, THAT
    THAT ENTRY POINT MUST BE INCLUDED ON THE END STMT IN THE
    ASSEMBLY JOB STREAM.
    -    MSGIPK182 IPK182 ALIGNMENT ERROR IN OPERAND 2
    THIS WARNING MSG MAY BE ISSUED DURING ASSEMBLY OF SOME DL/I-
    MODULES, SUCH AS DLZDLOC0 AND DLZTPRT0. MESSAGE MAY BE IGNORED.
    -    MSGIPK202 IPK202 TITLE NAME TOO LONG
    THIS WARNING MSG INDICATES THE MODULE TITLE STMT IS TOO LONG.
    MESSAGE MAY BE IGNORED.
    IN ADDITION, WHEN RELINKING CERTAIN DL/I MODULES FROM THE DL/I
    RELO LIBRARY AND CREATING DL/I PHASES, CERTAIN WARNING MSG'S MAY
    APPEAR ON THE CONSOLE AND ON SYSLST. DESCRIBED BELOW ARE SOME OF
    WHICH YOU MAY ENCOUNTER:
    -    MSG2158I 2158I NO CSECT LENGTH SUPPLIED
    THE END CARD DOES NOT CONTAIN THE LENGTH OF THE CONTROL SECTION.
    ALLOW THE JOB TO EXECUTE. IF EXECUTION FAILS, REASSEMBLE AND
    RELINK MODULE IN QUESTION. IF EXECUTION SUCCESSFUL IGNORE MSG.
    THIS MAY APPEAR LINKING DLZMPI00, DLZRRC00 AND A FEW OTHERS.
    -    MSG2199I 2199I ERROR HAS OCCURRED DURING LINKAGE EDITING
    SPECIFIC MSG WILL BE AVAILABLE ON SYSLST. REVIEW THE MESSAGES,
    TAKE ANY REQUESTED ACTION AND CONTINUE LINK EDIT JOB.
    -    MSG2139 2139I DUPLICATE SECTION DEFINITION  ** SECT.IGN **
    THIS MAY APPEAR WHEN LINKING A NUMBER OF DL/I PHASES AND THE
    ASSOCIATED MODULES AND CSETS INCLUDED. LINK SHOULD CONTINUE TO
    PROCESS, THEN REVIEW SYSLST OUTPUT FOR ANY ADDITIONAL INFO OR
    REQD. ACTION. THIS ARE THE DL/I PHASES FOR WHICH MSG MAY APPEAR:
    DLZBACK0 DLZBPC00 DLZBNUC0 DLZDBH00 DLZDHDS0 DLZDLA00 DLZDLBDP
    DLZDLBPP DLZDLR00 DLZDSEH0 DLZEXDFP DLZFSDP0 DLZLOGP0 DLZMPI00
    DLZRDBL0 DLZRRC00 DLZTPRT0 DLZUACB0 DLZUCUM0 DLZUDMP0 DLZURDB0
    DLZURGL0 DLZURGP0 DLZURGS0 DLZURGU0 DLZURG10 DLZURPR0 DLZURRL0
    DLZURUL0
    IN ADDITION FOLLOWING CSECTS (DUPL.SECTION NAMES) MAY ALSO
    APPEAR IN ABOVE MSG WHEN LINKING CERTAIN DL/I PHASES:
    DLZCONSL DLZDIMOD DLZLGPCN DLZLGPMT DLZRDR DLZRRC10 DLZTPCN
    IJJFCBIC IJJTCTL OPENWORK SCDCSECT
    -    CONTROL SECTIONS OF ZERO LENGTH IN INPUT
    THIS MAY APPEAR WHEN LINKING PHASES AS
    DLZBNUC0 DLZDDLE0 DLZDHDS0 DLZDLRA0 DLZMDLI0 DLZMPI00 DLZMPUR0
    DLZMSTP0 DLZMSTR0 DLZOLI00 DLZRRC00 DLZUACB0. LINK EDITING
    SHOULD CONTINUE AND YOU MAY IGNORE MESSAGES.
    -    UNRESOLVED EXTERNAL REFERENCES
    THIS MAY APPEAR FOR DLZDLBDP, DLZDLBPP, IJFVZZWN AND OTHERS.
    LINKAGE EDITOR SHOULD CONTINUE, IGNORE MESSAGE.
    -    POSSIBLE INVALID ENTRY POINT DUPLICATION IN INPUT
    THIS MAY APPEAR WHEN LINK EDITING PHASES DLZDHSD0 AND DLZUDMP0.
    LINK EDIT SHOULD CONTINUE. IGNORE MESSAGE.
    -    UNRESOLVED ADDRESS CONSTANTS
    THIS IS A VALID CONDITION WHEN LINK EDITING A NUMBER OF DL/I
    PHASES SUCH AS DLZURG10, DLZBACK0, (WITH CICS/VS) DLZDBH00 OR
    DLZACT (APPLICATION CONTROL TABLE, WHICH IS THE METHOD OF LINK-
    EDITING THE DL/I ONLINE NUCLEUS - DLZODP, DLZNUCXX AND DLZNUC),
    AND DLZRDBC0 (WHEN LINKED WITH DFHDBP AND DFHTBP). THE UN-
    RESOLVED EXTERNAL REFERENCES ARE CAUSED BY WXTRN'S WHICH CAUSE
    NO OPERATIONAL ERROR. CHECK THE SYSLST OUTPUT AND CONTINUE
    LINK EDIT PROCESSING.
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • INFORMATIONAL APAR.
    

APAR Information

  • APAR number

    II03105

  • Reported component name

    PB LIB INFO ITE

  • Reported component ID

    INFOPBLIB

  • Reported release

    001

  • Status

    CLOSED CAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1988-01-06

  • Closed date

    1988-02-19

  • Last modified date

    1989-12-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"Db2 for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: