APAR status
Closed as program error.
Error description
Node crashes with assert when the AFM fileset with active IO is unlinked.
Local fix
Stop AFM fileset and then unlink the fileset.
Problem summary
Node crashes with assert when the AFM fileset with active IO is unlinked
Problem conclusion
Benefits of the solution: Fixed the node crash by checking for the AFM fileset status before doing the file open. Work around: Stop AFM fileset and then unlink the fileset. Problem trigger: Fileset unlink with active IO. Symptom: Abend/Crash Platforms affected: All OS enviromenets Functional Area affected: AFM Customer Impact: High Importance
Temporary fix
Comments
APAR Information
APAR number
IJ20733
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
504
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-11-06
Closed date
2019-11-06
Last modified date
2019-11-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"504","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
06 November 2019