Error description
Permission denied for /proc/<PID>/cwd for program with different group and SGID Bit set.
Local fix
Problem summary
If the user is part of more than one group, and if the user's current primary group id is different from the binary group id, and set the sgid(g+s) on the bianry, then readlink() will fail with error EACCESS(return code 13).
Problem conclusion
There is a bug is checking group id of the user with the binary. Modified the code to fix the issue.