APAR status
Closed as program error.
Error description
Async release of resources is done by ROHA as background process. It can hang when running a command and will fail only after a timeout. If a node is rebooted when clasyncroha hung, rg acquire after reboot gets into config_too_long like below : clmanageroha: ERROR: Waited for 360 sec on asynchronous release of resources, but still in progress. Could not proceed, try again later on. RG acquire completes after config_timeout of 360 seconds.
Local fix
Clear the ODM after reboot of node when clasyncroha hung : print -- "HACMPdynresop:\\nvalue=\"\"" | ODMDIR=/etc/es/objrepos odmchange -o HACMPdynresop -q "key=REL_APPS"
Problem summary
If a node is rebooted when clasync roha is going on, post reboot rg acquire gets into config_too_long like below : clmanageroha: ERROR: Waited for 360 sec on asynchronous release of resources, but still in progress. Could not proceed, try again later on. RG acquire completes after config_timeout of 360 seconds.
Problem conclusion
Modified code to reset the REL_APPS value during node up
Temporary fix
Comments
APAR Information
APAR number
IJ16875
Reported component name
POWERHA SYSMIR
Reported component ID
5765H3900
Reported release
721
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2019-06-14
Closed date
2019-06-14
Last modified date
2019-06-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
POWERHA SYSMIR
Fixed component ID
5765H3900
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
19 October 2021