Direct link to fix
APAR status
Closed as program error.
Error description
When cluster services are started on node1 then clver is called to verify multiple conditions including the status of resources on all cluster nodes. If for example a volume group is varied on one of remote nodes and the volume group is not handled by PowerHA then this is apparently being recognized as an error condition. The following message is displayed on node1: WARNING: node2 has volume group name_vg varied on. This volume group is part of resource group name_rg, which is in the OFFLINE state on node2. Would you like to bring the resources of this resource group: name_rg offline, so that you can then move the resource group to a node other than node:node2 [Yes / No]: The question may be misleading and it has been requested to make this described more clearly and readable. Basically, if No is chosen as the majority does then the shared resources consistency may be compromised.
Local fix
There is no work-around to this issue.
Problem summary
While starting the cluster services, following message is not clear when some of the resources are online without RG is online on a node. WARNING: sapcl01b has volume group sap_vg varied on. This volume group is part of resource group sappr1_rg, which is in the OFFLINE state on node sapcl01b. Would you like to bring the resources of this resource group:sappr1_rg offline, so that you can then move the resource group to a node other than node:sapcl01b [Yes / No]:
Problem conclusion
Modified the existing verification message to make it more clear
Temporary fix
select yes option
Comments
APAR Information
APAR number
IJ13271
Reported component name
POWERHA SYSMIR
Reported component ID
5765H3900
Reported release
721
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2019-02-05
Closed date
2019-02-05
Last modified date
2019-05-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
POWERHA SYSMIR
Fixed component ID
5765H3900
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
19 October 2021