APAR status
Closed as program error.
Error description
Processes using CIFS mounts may hang in an infinite loop if a write operation fails, constantly using CPU. Processes hung in this state will have a stack like the following. mb_put_uio@AF50_21+000058 smb_write+00048C smbfs_writevnode+0000A8 cn_rdwr+000258 .hkey_legacy_gate+00004C vnop_rdwr+0001A4 vno_rw@AF17_5+000158 IPRA.$rwuio+0000D4 IPRA.$rdwr+00018C kewrite+0001A4 syscall+000228
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * Systems running the 7100-05 Technology Level with * any of the following filesets at or between the given levels: * MIN MAX FILESET * 7.1.5.0 7.1.5.30 bos.cifs_fs.rte **************************************************************** * PROBLEM DESCRIPTION: * Processes using CIFS mounts may hang in an * infinite loop if a write operation fails, * constantly using CPU. Processes hung in this * state will have a stack like the following. * mb_put_uio@AF50_21+000058 * smb_write+00048C * smbfs_writevnode+0000A8 * cn_rdwr+000258 * .hkey_legacy_gate+00004C * vnop_rdwr+0001A4 * vno_rw@AF17_5+000158 * IPRA.$rwuio+0000D4 * IPRA.$rdwr+00018C * kewrite+0001A4 * syscall+000228 **************************************************************** * RECOMMENDATION: * Install APAR IJ11402. ****************************************************************
Problem conclusion
Restore uio structure fields when necessary.
Temporary fix
Comments
7100-04 - use AIX APAR IJ13309 7100-05 - use AIX APAR IJ11402 7100-05 - use AIX APAR IJ11402 7200-01 - use AIX APAR IJ13810 7200-02 - use AIX APAR IJ10660 7200-03 - use AIX APAR IJ12374
APAR Information
APAR number
IJ11402
Reported component name
AIX V7.1
Reported component ID
5765H4000
Reported release
710
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-11-17
Closed date
2018-12-04
Last modified date
2019-11-14
APAR is sysrouted FROM one or more of the following:
IJ10660
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.1
Fixed component ID
5765H4000
Applicable component levels
R710 PSY U883013
UP19/05/01 I 1000
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11R"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]
Document Information
Modified date:
19 April 2022