Error description
mmhealth monitoring for keystone service for object protocol authentication can cause a system to run out of memory.
Local fix
na
Problem summary
mmhealth monitoring for keystone service for object protocol authentication can cause a system to run out of memory.
Problem conclusion
The keystone URL monitor code was fixed by using a single SSL certificate context instead of creating a new context on every monitor run. Work Around: Check the memory consumption of mmsysmon monitoring service and restart the service if required. Problem trigger : The monitoring of an external keystone service caused increasing mmsysmon service memory consumption. Symptom: "Out of memory: Kill process xxx (python)" messages in /var/log/messages Platforms affected: Linux only (CES nodes) Functional Area affected: CES Customer Impact: High Importance Changed Externals: None
Temporary fix
Comments
APAR Information
APAR number
IJ11284
Reported component name
SPEC SCALE STD
Reported component ID
5737F33AP
Reported release
502
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-11-15
Closed date
2018-11-15
Last modified date
2019-02-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SPEC SCALE STD
Fixed component ID
5737F33AP
Applicable component levels
R502 PSY U883600
UP18/12/18 I 1000
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"502","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
12 February 2019