ClearCase build tools may crash with "Module Not Found" exceptions if PATH environment variable redefined during the build.

Troubleshooting


Problem

When building in replicated VOBs using IBM Rational ClearCase build tools (clearmake, omake, clearaudit), the build tools may crash with a "module not found" (0xc06d007e) exception if IBM Rational Common Licensing is used.

Symptom

The following error may be present in the system event log:

    +-+-+-+-+-+-+-+-+-+-+

    Log Name:      Application

    Source:        Application Error

    Date:          5/31/2013 11:29:46 AM

    Event ID:      1000

    Task Category: Application Crashing Events

    Level:         Error

    Keywords:      Classic

    User:          N/A

    Computer:      failedhost.ibm.com

    Description:

    Faulting application name: clearmake.exe, version: 7.1209.0.138, time stamp: 0x50a30f58

    Faulting module name: KERNELBASE.dll, version: 6.1.7601.17965, time stamp: 0x506dbe50

    Exception code: 0xc06d007e

    Fault offset: 0x0000c41f

    Faulting process id: 0x1188

    Faulting application start time: 0x01ce5e0b4c414cda

    Faulting application path: C:\Program Files (X86)\IBM\RationalSDLC\ClearCase\bin\clearmake.exe

    Faulting module path: C:\Windows\syswow64\KERNELBASE.dll

    Report Id: 8a86517f-c9fe-11e2-805b-8851fb3f6283

    +-+-+-+-+-+-+-+-+-+-+



Additionally, the following message may be present one or more places in the build logs:
    clearmake[1]: Leaving directory `N:\test\dir1\make'

    *** Error code -1066598274

    clearmake: Error: Build script failed for "longtarget"



This is the decimal representation of the hexadecimal exception code in the system event log.

These errors will generally occur no more that 15-20 minutes into the build.

[{"Product":{"code":"SSSH27","label":"Rational ClearCase"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Component":"Clearmake - Clearaudit - Omake","Platform":[{"code":"PF033","label":"Windows"}],"Version":"7.0;7.0.1;7.1;7.1.1;7.1.2;8.0;8.0.1","Edition":"","Line of Business":{"code":"LOB77","label":"Automation Platform"}}]