IBM Support

IV39378: HA: GLVM TIMEOUT VALUE SET INCORRECTLY TO 1800

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The I/O timeout value for RPV devices should be set
    by PowerHA to be the "config_too_long" interval,
    with a maximum of 1800.  However, the comparison
    is made on an ASCII basis instead of a numeric
    basis, and therefore the maximum value is almost
    always chosen.  The logfile "hacmp.out" will show:
    
      set_client_iotimeout: EVENT_DURATION=180
      set_client_iotimeout: ((0==0))
      set_client_iotimeout: GROUP_DURATION=180
      set_client_iotimeout: ((TOTAL_DURATION=180+180))
      set_client_iotimeout: [[ 360 > 1800 ]]
      set_client_iotimeout: TOTAL_DURATION=1800
    
    
    The TOTAL_DURATION should have been set to 360.
    

Local fix

Problem summary

  • GLVM timeout value set incorrectly to 1800
    

Problem conclusion

  • Correct the syntax of the timeout comparison in
    the glvm_predisk_available script.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV39378

  • Reported component name

    POWERHA 6.1 BAS

  • Reported component ID

    5765H2300

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2013-04-05

  • Closed date

    2013-05-02

  • Last modified date

    2013-09-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IV43528

Fix information

  • Fixed component name

    POWERHA 6.1 BAS

  • Fixed component ID

    5765H2300

Applicable component levels

  • R610 PSY U860317

       UP13/09/03 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
19 October 2021