A fix is available
APAR status
Closed as program error.
Error description
When flashing newer Broadcom microcode to the HT-2000 I/O controller on the JS21 blade, the flash fails with an NVRAM write error which leaves the HT-2000 in an unusable state.
Local fix
Problem summary
Flashing of newer Broadcom microcode to HT-2000 I/O controller on JS21 blade fails with NVRAM write errors
Problem conclusion
Increase the NVRAM write operation completion wait time
Temporary fix
Comments
5300-08 - use AIX APAR IZ58374 5300-09 - use AIX APAR IZ69245 5300-10 - use AIX APAR IZ69362 5300-11 - use AIX APAR IZ67711 6100-04 - use AIX APAR IZ68037
APAR Information
APAR number
IZ58374
Reported component name
AIX 5.3
Reported component ID
5765G0300
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2009-08-14
Closed date
2009-11-26
Last modified date
2013-04-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
IZ66006 IZ66013 IZ66025 IZ67711 IZ68037 IZ69245 IZ69362 IZ71336
IZ71642 IZ71876 IZ99494 IV05848
Fix information
Fixed component name
AIX 5.3
Fixed component ID
5765G0300
Applicable component levels
R530 PSY U829564
UP10/03/23 I 1000
PTF to Fileset Mapping
U829564 devices.pci.14101403.rte 5.3.8.4