Error description

  • .
    ----------------------------- Test Environment Details
    ----------------------------- CLUSTER INFORMATION:2 nodes
    Cluster Nodes (Hostname/IP): Site A: r1r2m1p41(172.19.67.51)
    site B : r1r2m1p42(172.19.67.52) Cluster Access
    (User/Password): root/abc123) HMC/Console access: 172.19.69.5
    (GuestUser/ibm@123) Pre AIX Level : 1441D_61c Pre RSCT level :
    rmut1433a 3.2.0.0 RSCT_Build_Context=power Pre PowerHA : 610
    GOLD + SP16 Post AIX level: 1709A_71X RSCT LEVEL : rootas001a
    3.2.1.11 power PowerHA SM Level : 713 Gold + SP7 HA_SP: VG
    modification to 'critical' using clmgr is not working
    ================ Steps followed are:  1)installed caa aix
    1441D_61c 2)installed powerha 713 GOLD+ SP7 3) Created cluster
    and sites 4)Created VG 5)Modified VG as critical using the
    following command clmgr modify vg <VGNAME> critical=true Output
    is displayed as "clmgr: The cluster configuration has been
    changed - CRITICAL Volume Group VG01 has been added.  The
    configuration must be synchronized to make this change
    effective across the cluster" But, "critical" attribute's value
    in "clmgr query vg <VGNAME>" shows "false".  The same behavior
    is observed in Powerha 720 SP3
    .
    The details are:
    .
        clmgr q vg VG01 NAME="VG01" TYPE="SCALABLE"
        NODES="r1r2m1p41,r1r2m1p42" LOGICAL_VOLUMES="LV01,loglv01"
        PHYSICAL_VOLUMES="hdisk3@r1r2m1p41@00cde1376fafe841"
        MIRROR_POOLS="" STRICT_MIRROR_POOLS="no"
        RESOURCE_GROUP="RG01" AUTO_ACTIVATE="false" QUORUM="true"
        CONCURRENT_ACCESS="true" CRITICAL="false"
        ON_LOSS_OF_ACCESS="" NOTIFYMETHOD=""
        MIGRATE_FAILED_DISKS="false" SYNCHRONIZE="false"
        LOGICAL_TRACK_GROUP_SIZE="512"
        MAX_PHYSICAL_PARTITIONS="32768" PPART_SIZE="2048"
        MAX_LOGICAL_VOLUMES="256" MAJOR_NUMBER="40"
        IDENTIFIER="00cde13700004c000000015b0f132430"
        TIMESTAMP="58da498c20af3985" clmgr modify vg VG01
        CRITICAL=true clmgr: The cluster configuration has been
        changed - CRITICAL Volume Group VG01 has been added. The
        configuration must be synchronized to make this change
        effective across the cluster.# clmgr q vg VG01 NAME="VG01"
        TYPE="SCALABLE" NODES="r1r2m1p41,r1r2m1p42"
        LOGICAL_VOLUMES="LV01,loglv01"
        PHYSICAL_VOLUMES="hdisk3@r1r2m1p41@00cde1376fafe841"
        MIRROR_POOLS="" STRICT_MIRROR_POOLS="no"
        RESOURCE_GROUP="RG01" AUTO_ACTIVATE="false" QUORUM="true"
        CONCURRENT_ACCESS="true" CRITICAL="false"
        ON_LOSS_OF_ACCESS="" NOTIFYMETHOD=""
        MIGRATE_FAILED_DISKS="false" SYNCHRONIZE="false"
        LOGICAL_TRACK_GROUP_SIZE="512"
        MAX_PHYSICAL_PARTITIONS="32768" PPART_SIZE="2048"
        MAX_LOGICAL_VOLUMES="256" MAJOR_NUMBER="40"
        IDENTIFIER="00cde13700004c000000015b0f132430"
        TIMESTAMP="58da49b222543c73"
    

Local fix

Problem summary

  • Modification of vg as
    critical not effected.
    

Problem conclusion

  • Display Warning message when trying
    to mark vg as critical in
    "Fast Disk Takeover" mode.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV99384

  • Reported component name

    POWERHA SYSMIR

  • Reported component ID

    5765H3900

  • Reported release

    713

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2017-08-28

  • Closed date

    2017-10-13

  • Last modified date

    2017-10-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IV99385 IV99386

Fix information

  • Fixed component name

    POWERHA SYSMIR

  • Fixed component ID

    5765H3900

Applicable component levels

  • R713 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"713","Edition":"","Line of Business":{"code":"","label":""}}]