IBM Support

IV99364: EZU2:RSCT NOT FOUND ERROR SEEN IN THE EZUPDATE.LOG

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

Direct links to fixes

 

APAR status

  • Closed as program error.

Error description

  • ----------------------------- Test Environment Details
    -----------------------------
    .
    CLUSTER INFORMATION:2 nodes Cluster Nodes
    (Hostname/IP):d25m1c47.ausprv.stglabs.ibm.com,d25m1c48.ausprv.st
    glabs.ibm.com,
    Cluster Access (User/Password): root/d0ntknow) HMC/Console
    access: r1r9hmc (hscroot/abc123) AIX Level : 1711A_72D RSCT
    .
    HA_SP:RSCT not found error seen in the EZUpdate.log
    ================
    .
    Steps followed are:  1)installed caa aix 1711A_72D 2)installed
    powerha 721 GOLD +SP1 3)created cluster and started the
    services 4)started the services and cluster is stable on both
    the nodes 5)Ran EZUpdate command to install and reject the fix
    .
    command o/p is shown below for reject :
    .
    root @ d25m1c47: /home
    .
        /usr/es/sbin/cluster/utilities/cl_ezupdate -R -N
        d25m1c47,d25m1c48 -s /home Checking for root authority...
        Running as root.  Checking for AIX level...  The installed
        AIX version is supported.  Checking for PowerHA
        SystemMirror version...  The installed PowerHA SystemMirror
        version is supported.  Checking for clcomd communication on
        all nodes...  clcomd on each node can both send and receive
        messages.  Checking for lpps and Ifixes from source:
        /home...  Build lists of filesets that can be apply reject
        or commit on node d25m1c48 There is nothing to install on
        node: d25m1c48 from source: /home The following Ifix will
        be removed on node: d25m1c48 during reject operation:
        dummy.  Before to reject filesets and or Ifixes, the node:
        d25m1c48 will be stopped in unmanage mode.  Build lists of
        filesets that can be apply reject or commit on node
        d25m1c47 There is nothing to install on node: d25m1c47 from
        source: /home The following Ifix will be removed on node:
        d25m1c47 during reject operation: dummy.  Before to reject
        filesets and or Ifixes, the node: d25m1c47 will be stopped
        in unmanage mode.  Stopping the node d25m1c48 in
        non_disruptive mode.  Stopping PowerHA cluster services on
        node: d25m1c48 in offline mode...  d25m1c48: 0513-004 The
        Subsystem or Group, clinfoES, is currently inoperative.
        d25m1c48: 0513-044 The clevmgrdES Subsystem was requested
        to stop.
        ..
        "d25m1c48" is now offline.
    .
    d25m1c48: Jun 7 2017
    04:15:33/usr/es/sbin/cluster/utilities/clstop: called with
    flags -N -g Removing Ifix: dummy on node: d25m1c48...  Starting
    the node: d25m1c48...  Starting cluster manager daemon:
    clstrmgrES...  Starting PowerHA cluster services on node:
    d25m1c48 in manual mode...
    .
    cl_rc.cluster: Error: Changes have been made to the Cluster
    Topology or Resource configuration. The Cluster Configuration
    must be synchronized before starting Cluster Services.
    Stopping the node d25m1c47 in non_disruptive mode.  Removing
    Ifix: dummy on node: d25m1c47...  Starting the node:
    d25m1c47...  Starting cluster manager daemon: clstrmgrES...
    WARNING: Cluster service are down on node d25m1c48 in the
    state:OFFLINE.  WARNING: Cluster service are down on node
    d25m1c47 in the state:UNMANAGED.
    .
    (0) root @ d25m1c47: /var/hacmp/EZUpdate
    .
        cat EZUpdate.log | grep 1522
        /usr/es/sbin/cluster/utilities/cl_ezupdate: line 1522:
        RSCT: not found
    .
    EZUpdate.log o/p:
    .
    INF: _.clrsh_cmd()Ý1160¨(19.785): command output='caavg_private
    rootvg' INF: node.build()Ý375¨(19.816):
    d25m1c48.active_conc_vg=""
    /usr/es/sbin/cluster/utilities/cl_ezupdate: line 1522: RSCT:
    not found < ======================== INF:
    check_if_nfs_path()Ý378¨(19.853): command returns code: 0 INF:
    check_if_nfs_path()Ý379¨(19.853): command
    output='iofnim.aus.stglabs.ibm.com:/nim/build_net 62914560
    11997696 81% 39878 3% /test haserver:/ha_images 1887436800
    195689904 90% 1664165 8% /mnt' INF: check_lpps()Ý572¨(19.857):
    Entered check_lpps INF: _.clrsh_cmd()Ý1134¨(19.857): execute
    cmd: /usr/bin/test -d /home 2>&1 INF:
    _.clrsh_cmd()Ý1159¨(19.867): command returns code:0 INF:
    _.clrsh_cmd()Ý1160¨(19.
    .
    exepected result:
    .
    EZUpdate.log should not contain code errors
    

Local fix

Problem summary

  • cl_ezupdate log file displays absurd message
    

Problem conclusion

  • Replace (:) with (#) from comments secion
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV99364

  • Reported component name

    POWERHA SYSMIR

  • Reported component ID

    5765H3900

  • Reported release

    721

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2017-08-28

  • Closed date

    2017-10-05

  • Last modified date

    2017-10-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    POWERHA SYSMIR

  • Fixed component ID

    5765H3900

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"721","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
19 October 2021