A fix is available
APAR status
Closed as program error.
Error description
If shared objects for 32 and 64 bits libraries have the same name, ldd might fail to find the correct dependencies from the correct library. It will use the first found object either it is 32 or 64 bits, either the application is 32 or 64bits. Thus is might find 32 bit applications depending on 64 bit libraries, or the reverse.
Local fix
None if customer can't change the 32 & 64 objects names in the libraries. Otherwise differenciate 32 & 64 names in libraries, I.E _32 and _64.
Problem summary
If shared objects for 32 and 64 bits libraries have the same name,ldd might fail to find the correct dependencies from the library.
Problem conclusion
Fixed the code to find the correct dependencies from the library.
Temporary fix
Comments
APAR Information
APAR number
IV95054
Reported component name
AIX V7.2
Reported component ID
5765CD200
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2017-04-12
Closed date
2017-04-12
Last modified date
2017-10-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.2
Fixed component ID
5765CD200
Applicable component levels
R720 PSY U869982
UP17/10/12 I 1000
PTF to Fileset Mapping
U869982 bos.rte.bind_cmds 7.2.2.0
[{"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SSVEF8","label":"AIX 7.2 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB68","label":"Power HW"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11S","label":"AIX 7.2 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]