IBM Support

IV93790: USING CLOUDDEV CAN RESULT IN A DEVRESET DURING SYSTEM REBOOT. APPLIES TO AIX 7100-04

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customers are installing cloud-init and then shutting down to
    capture the image (per PowerVC recommendation).  Only to later
    reboot the capture system and notice that devreset has
    occurred on their system.
    This situation occurs because the ibm,aix-clearODMdata NVRAM
    variable is not being set prior to shutdown.
    

Local fix

Problem summary

  • Customers are installing cloud-init and then shutting down to
    capture the image (per PowerVC recommendation).  Only to later
    reboot the capture system and notice that devreset has
    occurred on their system.
    This situation occurs because the ibm,aix-clearODMdata NVRAM
    variable is not being set prior to shutdown.
    

Problem conclusion

  • Update the internal system  command, bootutil, to support the
    setting of the ibm,aix-clearODMdata NVRAM variable.  The
    cloud-init program will use the bootutil command to set the
    NVRAM variable prior to enabling clouddev on the system.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV93790

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-02-28

  • Closed date

    2017-02-28

  • Last modified date

    2017-04-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IV93803 IV93822 IV93848 IV93858 IV93866

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U873608

       UP17/04/07 I 1000

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11R"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date: