IBM Support

IV88011: SAR MAY CORE DUMP AFTER REBOOT APPLIES TO AIX 7100-04

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If the number of VCPUs decrease after reboot,
    the sar command will core dumps in the following stack :
    malloc_y(0x178, 0x0, 0xf071224c, 0xf06a8fe0, 0x45300000,
    0x45300000, 0x10019f68, 0x0) at 0xd012a68c
    malloc_common@AF104_87(??) at 0xd0112b24
    malloc(??) at 0xd01128a8
    calloc_common(??, ??) at 0xd0111f5c
    prtopt() at 0x100084ec
    prpass() at 0x10016958
    main(??, ??) at 0x10000de8
    

Local fix

  • N/A
    

Problem summary

  • Sar core dumps when used with multiple options and the number
    of cpus decrease after reboot.
    

Problem conclusion

  • Code changes so that memory is reallocated and sar doesnot
    dump core when used with multiple options.
    

Temporary fix

Comments

  • 6100-09 - use AIX APAR IV87793
    7100-04 - use AIX APAR IV88011
    7200-01 - use AIX APAR IV87974
    

APAR Information

  • APAR number

    IV88011

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-08-15

  • Closed date

    2016-08-15

  • Last modified date

    2017-01-20

  • APAR is sysrouted FROM one or more of the following:

    IV81608

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U862914

       UP16/10/25 I 1000

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11R"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date: