Error description
Taking an iptrace when using an adapter using shientdd results in all out going packets being seen twice in the packet capture. When using an adapter using the elxentdd driver, the duplication is not seen.
Local fix
Problem summary
Taking iptrace shows packet twice when physical adapter is under SEA or etherchannel.
Problem conclusion
Entcore is fixed to ignore packet tracing when device is under SEA or etherchannel.
Temporary fix
Comments
APAR Information
APAR number
IV86813
Reported component name
AIX V7.1
Reported component ID
5765H4000
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-07-12
Closed date
2016-07-12
Last modified date
2017-02-08
APAR is sysrouted FROM one or more of the following:
IV86678
APAR is sysrouted TO one or more of the following:
U876085
Fix information
Fixed component name
AIX V7.1
Fixed component ID
5765H4000
Applicable component levels
R710 PSY U876085
17/02/08 I 1000