IBM Support

IV85994: STNFS_RECOVER_FH CRASHES THE SYSTEM APPLIES TO AIX 7200-01

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • system crashes in stnfs_recover_fh()
    

Local fix

  • there is none
    

Problem summary

  • stnfs_recover_fh crashes system
    

Problem conclusion

  • Part of the code which is accessing data structure is protected
    under mutex lock to avoid corruption.
    

Temporary fix

Comments

  • 7200-01 - use AIX APAR IV85994
    

APAR Information

  • APAR number

    IV85994

  • Reported component name

    AIX V7.2

  • Reported component ID

    5765CD200

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2016-06-20

  • Closed date

    2016-06-20

  • Last modified date

    2016-11-09

  • APAR is sysrouted FROM one or more of the following:

    IV84265

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.2

  • Fixed component ID

    5765CD200

Applicable component levels

  • R720 PSY U856903

       UP16/10/28 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SSVEF8","label":"AIX 7.2 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB68","label":"Power HW"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11S","label":"AIX 7.2 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date:
10 September 2025