Error description
Some ethernet adapters cause transmit failures in half duplex mode with 10 MBPS speed. GOENT_TX_ERR errors will be seen in the error log. . After the transmit errors, the adapter hangs and only way to recover is to reboot. . Look for collision errors as a signature for this problem. . The affected adapters are FC (feature code): 5701 5706 5740 5767 5271 5717
Local fix
Use full duplex mode to work around this issue.
Problem summary
GOENT_TX_ERR errors in AIX error log when running the Ethernet adapter 10Mbit Half Duplex mode.
Problem conclusion
Increase Tx timeout value to 1000 milliseconds to allow for deferred transmits and transmit collisions which can occur in a half duplex environment.
Temporary fix
Comments
APAR Information
APAR number
IV83260
Reported component name
AIX V7.1
Reported component ID
5765H4000
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-04-01
Closed date
2016-04-30
Last modified date
2017-01-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
IV84477 IV84479 IV84485 IV88150
Fix information
Fixed component name
AIX V7.1
Fixed component ID
5765H4000
Applicable component levels
R710 PSY U872419
UP17/01/19 I 1000