IBM Support

OA50101: PREDICTIVE FAILURE ANALYSIS (PFA) ABEND9C6 RSN0030000A AIR038I DIAGXX VSM TRACK

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • At z/OS 2.2 (HBB77A0), PFA experiences an Abend9C6 RSN0030000A.
    This occurs with the PFA_COMMON_STORAGE_USAGE check as it
    performs the first collection after the DIAGxx setting of VSM
    TRACK has CSA, SQA, or both set to OFF.  This collection may be
    the first collection after PFA is started if it was set prior to
    PFA being started.
    
    Following the abend, PFA hangs and latch contention is observed
    with d grs,c
    
    Output of d grs,c similar to:
    ISG343I 16.31.03 GRS STATUS 080
    NO ENQ RESOURCE CONTENTION EXISTS
    LATCH SET NAME:  SYSPFA.PFA_COMMON_STORAGE_USAGELATCHSET
    CREATOR JOBNAME: PFA       CREATOR ASID: 002B
    LATCH NUMBER:  0
    REQUESTOR ASID  EXC/SHR    OWN/WAIT  WORKUNIT  TCB  ELAPSED TIME
    PFA       002B  EXCLUSIVE  OWN       008D8D90   Y   00:05:07.603
    PFA       002B  SHARED     WAIT      008F8588   Y   00:00:18.124
    

Local fix

  • 1. Cancel PFA to eliminate the Latch Contention
    2. Create or modify your DIAGxx to include:
       VSM TRACK CSA(ON) SQA(ON)
    3. Dynamically put this new DIAGxx in effect:
       SET DIAG=xx
    4. Restart PFA
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of HBB77A0 exploiting the          *
    *                 Predictive Failure Analysis (PFA).           *
    ****************************************************************
    * PROBLEM DESCRIPTION: Predictive Failure Analysis (PFA)       *
    *                      abended with AbendS9C6 RSN0030000A.     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Predictive Failure Analysis (PFA) abended with Abend9C6
    RSN0030000A in AIRHMCSC during collection for the
    PFA_COMMON_STORAGE_USAGE check.
    The abend only occurs if installation has a DIAGxx setting
    with the VSM TRACK setting having CSA(OFF), SQA(OFF) or both
    set to OFF such as VSM TRACK CSA(OFF) SQA(OFF).  After the
    abend PFA hangs because of latch contention.
    

Problem conclusion

  • Code has been changed to prevent the abend condition.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA50101

  • Reported component name

    Z/OS PFA

  • Reported component ID

    5752SCPFA

  • Reported release

    7A0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-03-15

  • Closed date

    2016-03-24

  • Last modified date

    2016-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA81138

Modules/Macros

  • AIRHMCSC
    

Fix information

  • Fixed component name

    Z/OS PFA

  • Fixed component ID

    5752SCPFA

Applicable component levels

  • R7A0 PSY UA81138

       UP16/04/06 P F604

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 May 2016