IBM Support

OA48704: ABEND U0910 RUNNING VMA AFTER INSTALLING PTFS FOR OA47384 OR OA41969

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • While the PTFs for OA47384 the corrected the reported U0910
    abends, other cases have been found where a U0910 abend can
    occur.
    In the reported case, the VOLUME REPORT had been requested.
    

Local fix

  • Remove PTFs for OA47384 and OA41969. These are:
    UA76397, UA76398, UA76832, UA76833
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of VMA with print fields that might    *
    *                 overflow.                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: If VMA output fields overflow, a user   *
    *                      910 abend will occur and processing     *
    *                      will stop.                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    U0910 abends may occur with VMA.
    

Problem conclusion

  • Instead of a U0910 abend occuring when fields overflow,
    a message will be issued, the field will be filled with
    exclamation points and processing will continue.
    
    SC23-6859-01
    DFSMS: Using the Volume Mount Analyzer
    Messages:
    GFTA208T  TAPE BLOCKS GREATER THAN 2,147,483,647
    Explanation:  A data set or segment of a data set on a single
    tape has more than 2,147,483,647 blocks.  The program will
    issue a user 908 abend.
    User Response:  Contact volume mount analyzer support.
    
    GFTA209T  KB/OPENS GREATER THAN 2,147,483,647
    Explanation:  Average size per OPEN is greater than
    2,147,483,647 KB.  The program will issue a user 909 abend.
    User Response:  Contact volume mount analyzer support.
    
    GFTA210W  PRINT VALUE OVERFLOW
    Explanation:  A value to be printed in a report has
    overflowed.
    The program will print the field as a series of exclamation
    points and set the return code to four.
    User Response:  Contact volume mount analyzer support.
    
    GFTA211T  TRACKS REQUIRED GREATER THAN 2,147,483,647
    Explanation:  The number of 3390 tracks required for the data
    or volume is greater than 2,147,483,647.  The program will
    issue a user 911 abend.
    User Response:  Contact volume mount analyzer support.
    
    Report changes:
    The 3390-3 TRACKS field in the VOLUME REPORT may contain six
    digits followed by a K or an M (for 1000s of bytes or 1000000s
    of bytes.)
    
    The AVG PER DATA SET field in the TAPE DATA SET STATISTICS
    report can be in MB or GB.
    
    If a report field overflows, it will be printed with all 9s.
    
    See field descriptions printed in the reports for other changes.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA48704

  • Reported component name

    VOL MOUNT ANALY

  • Reported component ID

    5695DF116

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-08-20

  • Closed date

    2015-10-06

  • Last modified date

    2016-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA79277 UA79278 UA79279 OA49066

Modules/Macros

  • GFTAPRNT GFTAVMA  GFTAXTR  GFTCCBND
    

Publications Referenced
SC23685901    

Fix information

  • Fixed component name

    VOL MOUNT ANALY

  • Fixed component ID

    5695DF116

Applicable component levels

  • RD10 PSY UA79277

       UP16/01/22 P F601 Ø

  • R210 PSY UA79278

       UP16/01/22 P F601 Ø

  • R220 PSY UA79279

       UP16/01/22 P F601 Ø

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: