A fix is available
APAR status
Closed as unreproducible in next release.
Error description
New Function
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IOCP users requiring support for the * * D/T2827 IBM zEnterprise EC12. * * D/T2828 IBM zEnterprise EC12. * **************************************************************** * PROBLEM DESCRIPTION: IOCP New Function * **************************************************************** * RECOMMENDATION: * **************************************************************** This PTF introduces a new release of ICP IOCP and is VERSION 4 RELEASE 1 LEVEL 2 (4.1.2) of the program. ICP IOCP supports the 2827 and 2828 zEnterprise EC12. PROBLEM CONCLUSION: * ICP IOCP VERSION 4 RELEASE 1 LEVEL 2 (4.1.2) provides the following support: - The 2828 Models (H06, H13) are supported with SYSTEM=(2828,1). IOCP ignores the MAXDEV keyword on the RESOURCE statement and reserves the maximum number of devices for this model. Also, IOCP reserves the maximum number of channel subsystems (CSSs) and logical partitions for these models. - The 2827 Models (H20, H43, H66, H89, HA1) are supported with SYSTEM=(2827,1). IOCP ignores the MAXDEV keyword on the RESOURCE statement and reserves the maximum number of devices for this model. Also, IOCP reserves the maximum number of channel subsystems (CSSs) and logical partitions for these models. - IOCP continues to use a variable amount of storage based on the type of IOCDS it is processing. IOCP requires 130M for the 2828 and 2827 CPC. - For 2827 and 2828 models: + ESCON channels CHPID (TYPE=IQD, CBY, CVC, CTC, CNC) are no longer supported. * * Documentation Changes: There is a new publication "Input/Output Configuration Program User's Guide for ICP IOCP" which has order number SB10-7037-11. The publication is available using Resource Link at http://www.ibm.com/servers/resourcelink by selecting section: Library > zEnterprise System, EC12 * EC (Engineering Change) Information: This PTF level of ICP IOCP contains support for IBM zEnterprise EC12 central processor complexes (CPCs). See Usage Notes for further information. * Information on equivalent STAND-ALONE IOCP, z/OS IOCP, z/VM IOCP, and z/VSE IOCP follows: * * - Equivalent STAND-ALONE IOCP for ICP IOCP version 4.1.2 is in the listed EC's. The EC's listed are the first levels shipped with this release of IOCP. EC MACHINE TYPE H49564 2827 H49564 2828 * - Equivalent z/OS, z/VM, and VSE IOCP is shipped via the listed APARs. OPERATING SYSTEM APAR z/OS OA42013 z/VM VM65278 z/VSE DY47476, DY47477 * * The EC level of the CPC can be determined from the Hardware Management Console or Support Element by doing the following: 1. Open 'Task List' from the 'Views' area. 2. Open 'Change Management' from the 'Task List Work Area'. 3. Open 'Groups' from the 'Views' area. 4. Open the group that contains the CPC you are interested in. 5. Select the CPC. 6. Open 'System Information' in the 'Change Management' tasks area. * The STAND-ALONE IOCP version and release can be determined by looking at the header lines of the IOCP reports produced by STAND-ALONE IOCP. The STAND-ALONE IOCP version and release can also be determined from the Hardware Management Console or Support Element by doing the following (begin with step 7 for the Support Element console): 1. Open 'Task List' from the 'Views' area. 2. Open 'Recovery' from the 'Task List Work Area'. 3. Open 'Groups' from the 'Views' area. 4. Open the group that contains the CPC you are interested in. 5. Select the CPC. 6. Open 'Single Object Operations' in the 'Recovery' tasks area. 7. Open 'Task List' from the 'Views' area. 8. Open 'CPC Configuration' from the 'Task List Work Area'. 9. Open 'Groups' from the 'Views' area. 10. Open 'Images' from the 'Groups Work Area'. 11. Select the image to run STAND-ALONE IOCP. 12. Open 'Input/output (I/O) configuration' in the 'CPC Configuration' tasks area. 13. Select 'View' pull-down. 14. Select 'Configuration program level'. * Usage Notes: 1. If you are currently using a release of ICP IOCP and you do not plan on upgrading to one of the listed EC's, you can still install this PTF and replace your existing ICP IOCP. The 2828 model must power-on reset with an IOCDS written by the ICP IOCP shipped by this PTF. The 2084, 2086, 2094, 2096, 2097, 2098, 2817, 2818 and 2827 models can power-on reset with an IOCDS written by the ICP IOCP shipped by this PTF. Also, the 2084, 2086, 2094, 2096, 2097, 2098, 2817, 2818 and 2827 models can still power-on reset with an IOCDS that was written by your previous release of ICP IOCP. There is no requirement that you write an IOCDS with the ICP IOCP shipped by this PTF and perform a power-on reset after the PTF has been installed. 2. Any IOCDS previously created by an ICP version of IOCP (z/OS, VM, VSE, or STAND-ALONE) can be reported on by the ICP version of IOCP shipped by this PTF. 3. Any IOCDS previously created by another version of IOCP (e.g. IYP IOCP) cannot be reported on by the ICP version of IOCP shipped by this PTF or by the STAND-ALONE equivalent version of the ICP IOCP program. (For HCD users, HCD manages the correlation of IOCP versions to CPC model for you.) 4. If you are upgrading to a 2828 model, you must power-on reset with an IOCDS written for the 2828. Following an upgrade, you cannot power-on reset with an IOCDS that was written for the prior CPC unless the 2828 IOCDS was written in preparation of an upgrade. 5. If you are upgrading to a 2828 model, IBM recommends writing an IOCDS to your current 2097 or 2817 CPC as described here. Use IOCP execution paramenter CHECKCPC=NO or HCD option 'Write IOCDS in preparation of upgrade'. The IOCDS will be unusable until your CPC has been upgraded to a 2828. Inform the installing service representative that you have pre-written a 2828 IOCDS and which IOCDS should be selected after the upgrade. 6. Although FMID HIO1104 also includes support for IXPIOCP (3090, 9021, 9121, and 9221 only), IZPIOCP (2003, 3000, 7060, 9021, 9121, 9672, and 9674 only), and IYPIOCP (2064 and 2066), these programs are not affected by this PTF. Program IOPIOCP (3090 only) will be reused at some point in the future for a new processor.
Problem conclusion
Temporary fix
Comments
ž**** PE13/09/16 PTF IN ERROR. SEE APAR OA43383 FOR DESCRIPTION
APAR Information
APAR number
OA42013
Reported component name
IOCP COMMON
Reported component ID
566529101
Reported release
104
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-04-17
Closed date
2013-07-24
Last modified date
2014-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA90663
Modules/Macros
ICPCARDS ICPCARDW ICPCARDX ICPCARDY ICPCARDZ ICPCFRST ICPCGET ICPCGNDS ICPCINIT ICPCIOCP ICPCIOCU ICPCIODV ICPCMSG ICPCPCHK ICPCPUT ICPCRDDS ICPCRPT ICPCRPTX ICPCRTNS ICPCRTNX ICPCWTDS ICPPCNTL ICPPMVS
| SB10703711 |
Fix information
Fixed component name
IOCP COMMON
Fixed component ID
566529101
Applicable component levels
R104 PSY UA90663
UP13/07/31 P F307
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"104","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"104","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
04 December 2014