A fix is available
APAR status
Closed as program error.
Error description
If an FC adapter is connected to a public loop, it is possible that it will fail to configure any attached devices.
Local fix
Problem summary
If an FC adapter is connected to a public loop, it is possible that it will fail to configure any attached devices.
Problem conclusion
Correct the state machine to correctly handle implicit logouts from the switch in a public loop context.
Temporary fix
Comments
6100-06 - use AIX APAR IZ97099 7100-00 - use AIX APAR IZ97027
APAR Information
APAR number
IZ97027
Reported component name
AIX V7.1
Reported component ID
5765H4000
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2011-03-21
Closed date
2011-03-21
Last modified date
2013-04-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.1
Fixed component ID
5765H4000
Applicable component levels
R710 PSY U843734
UP11/05/12 I 1000
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11R","label":"AIX 7.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
16 April 2013