Error description

  • SQLCode -450 after Decrypt and Re-Encryption of Table.
    Generated message:
    
    DSNT408I  SQLCODE = -450, ERROR: USER-DEFINED FUNCTION OR STORED
    PROCEDURE ENCVCS48, PARAMETER NUMBER 6, OVERLAYED STORAGE BEYOND
    ITS DECLARED LENGTH
    
    SQLCODE450 DEC-39
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IBM InfoSphere Guardium Data Encryption  *
    *                 for DB2 and IMS Databases Version 1 Release  *
    *                 2 users.                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: SQLCode -450 after Decrypt and          *
    *                      Re-Encryption of Table                  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    SQLCode -450 after Decrypt and Re-Encryption of Table.
    Generated message:    DSNT408I  SQLCODE = -450, ERROR:
    USER-DEFINED FUNCTION OR STORED PROCEDURE ENCVCS48,
    PARAMETER NUMBER 6, OVERLAYED STORAGE BEYOND ITS
    DECLARED LENGTH.
    

Problem conclusion

  • Code has been added to correct this issue.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI44129

  • Reported component name

    DATA ENCRYPTION

  • Reported component ID

    5655P0300

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-06-30

  • Closed date

    2015-09-03

  • Last modified date

    2015-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI30838

Modules/Macros

  • DECENUP0
    

Fix information

  • Fixed component name

    DATA ENCRYPTION

  • Fixed component ID

    5655P0300

Applicable component levels

  • R120 PSY UI30838

       UP15/09/16 P F509

Fix is available