IBM Support

MF60894 - LIC-MEDIA-TAPE iotapepaths macro output has duplicate librar

PTF Cover Letter


PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

LIC-MEDIA-TAPE iotapepaths macro output has duplicate librar


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED           PTF/FIX  LEVEL

TYPE PROGRAM  RELEASE   NUMBER   MIN/MAX  OPTION
---- -------- --------- -------  -------  ------
PRE  5770999  V7R2M0    MF59075   00/00    0000



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the 'IBM License Agreement for Machine
Code', the terms of which were provided in a printed document that was
delivered with the machine.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.





APAR Error Description / Circumvention

-----------------------------------------------
When using the iotapepaths advanced analysis macro, a library
resource may be displayed more than once.

CORRECTION FOR APAR MA45069 :
-----------------------------
Apply this fix to display each resource only one time.

CIRCUMVENTION FOR APAR MA45069 :
--------------------------------
None.


Activation Instructions


None.




Special Instructions


********************************************************************
THE FOLLOWING ARE SUPERSEDED SPECIAL INSTRUCTIONS. IF THE SUPERSEDED
PTF HAS ALREADY BEEN APPLIED AND ITS SPECIAL INSTRUCTION FOLLOWED,
IT IS NOT NECESSARY TO FOLLOW THAT SPECIAL INSTRUCTION AGAIN.
********************************************************************

SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF MF60425 :
=================================================

iotapepaths advanced analysis macro:
The first input parameter is a hardware resource name, one of
1. Blank        Report all tape resources
2. IOP name     Report tape resources configured on this IOP
3. TapeLibrary  Report tape resources associated with this
logical tape library
4. TapeDevice   Report all the paths to the resource
Additional keywords may be specified:
-NOHEAD         Omit the title line from the output
-VIEW sort      Specify how the output is sorted, where sort is:
LIBRARY   Report drives under controlling library
DEVICE    Report all paths to a drive when the first one
is encountered in the report output.

Output format:
Columns  Title            Meaning
1-10     RSC_NAME__       Hardware Resource Name reported
12-19    CCIN-MOD         Device type and model
21-35    SERIAL_________  Device serial number
37-40    PATH             Tape device path number
42-51    LIBRARY___       Tape library if device is in a library
53-54    CP               Number of control paths
56-65    IOP_______       controlling IOP resource name
67-70    PORT             IOP port the device is attached to
71-87    STATUS__________ Description of device status
89-104   WWID____________ Device world wide ID
106-113  LEVEL___         Firmware level active in the device


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   MF60425      LIC-MEDIA-TAPE Advanced Analysis Tape Path Report

Summary Information

System..............................i
Models..............................
Release.............................V7R2M0
Licensed Program...............5770999
APAR Fixed..........................View details for APAR MA45069
Superseded by:......................View fix details for PTF MF66835
Recompile...........................N
Library.............................QSYS
MRI Feature ........................NONE
Cum Level...........................C6127720


IBM i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15V","label":"PTF Cover Letters - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R2M0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG16F","label":"PTF Cover Letters - IBM i 7.2 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R2M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
31 March 2020