IBM Support

MF54706 - LIC - INCORROUT pick up 01B6 ses code

PTF Cover Letter


PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

LIC - INCORROUT pick up 01B6 ses code


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED      PTF/FIX  LEVEL

TYPE PROGRAM  REL  NUMBER   MIN/MAX  OPTION
---- -------- ---  -------  -------  ------
NONE



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the 'IBM License Agreement for Machine
Code', the terms of which were provided in a printed document that was
delivered with the machine.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.


APAR Error Description / Circumvention

-------------------------------------------------
Addresses the logging of SRC 3002 (src509a3002)

CORRECTION FOR APAR 'MA41651' :
-------------------------------
When applying this PTF, the partition may take an extended time
to IPL and the partition may appear to hang at SRC C6004057
during this time.  To determine the additional amount of time
needed to complete the IPL, take the number of 5886 drawers
assigned to this partition and multiply that by 4.  That is the
number of minutes needed to complete the code updates to the
5886 drawers before the IPL can continue.

A workaround to shorten the amount of time needed to complete
the IPL is to do a manual IPL to DST when applying this PTF and
wait at DST for the code updates to complete.  To determine how
many minutes to wait at DST: Multiply the maximum number of
drawers attached to any one I/O adapter by 4.  The largest
configuration possible would require 24 minutes.  After this
amount of time has elapsed, you may continue with a Normal IPL.

CIRCUMVENTION FOR APAR 'MA41651' :
----------------------------------
None.


Activation Instructions


IPL Partition for fix to apply.




Special Instructions


This code will be applied after IPL.

********************************************************************
THE FOLLOWING ARE SUPERSEDED SPECIAL INSTRUCTIONS. IF THE SUPERSEDED
PTF HAS ALREADY BEEN APPLIED AND ITS SPECIAL INSTRUCTION FOLLOWED,
IT IS NOT NECESSARY TO FOLLOW THAT SPECIAL INSTRUCTION AGAIN.
********************************************************************

SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF MF53280:
================================================

This PTF will be automatically permanently applied.
This fix is activated during the next IPL of the system after the PTF
has been applied.

SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF MF47639:
================================================

This PTF will be automatically permanently applied.
IPL Partition for fix to apply.


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   MF53280      LIC - INCORROUT pick up 01B5 ses code
   MF47639      LIC - INCORROUT pick up level 0197 ses code

Summary Information

System..............................i
Models..............................
Release.............................V6R1M1
Licensed Program...............5761999
APAR Fixed..........................View details for APAR MA41651
Superseded by:......................
Recompile...........................N
Library.............................QSYS
MRI Feature ........................NONE
Cum Level...........................C2122610


System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15V","label":"PTF Cover Letters - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V6R1M1","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG16A","label":"PTF Cover Letters - i5\/OS V6R1 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V6R1M1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 May 2012