How to Clear a hung session (SCI85448)

Question & Answer


Question

How to Clear a hung session (SCI85448)

Cause

Answer

1. Issue a ceuacq to determine the SID to be terminated.



  • issue a cmustop -s <sid>? where <sid> is the session id number for the the session in question

  • issue a cmusession to determine is the session (SID#) has terminated

2. If the CMUSTOP -s# does not terminate the session,



  • issue the? cmusession command to? find the Process ID (PID) associated with the Session ID (SID)

  • issue a kill -15 <PID#>? ? where <PID#> is the process ID of the session to be killed.?

  • issue a cmurefresh

3. Otherwise Recycle the protocol? daemon associated with the hung sessions



  • Cmusession

  • cmustop -s? <protocol daemon Session ID>

  • Restart the protocol daemon? "Reference YOUR ceustartup script for the proper parameters.

  • issue a cmurefresh

? 4. Last resort:



  • recycle Connect:Enterprise

  • cmushutdown

  • ceustartup or ceustartup.trace

?

[{"Product":{"code":"SSFVK3","label":"IBM Sterling Connect:Enterprise for UNIX"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Not Applicable","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]