IBM Support

Creating DataStage Job Log without access to DataStage

Troubleshooting


Problem

Users who do not have access to DataStage encounter the following error message when executing the following dsjob command to produce a job report file: dsjob -logdetail ERROR: Failed to open project Status code = 39202

Resolving The Problem

The following permissions must be set in the DSEngine directory:

  1. The group other must be set to r-x for all files in this directory.
  2. The unohist file must have permissions of rw-rw- rw- (666).
  3. In $DSHOME/catdir following permissions must be set as follows:

chmod -R o+w *

[{"Product":{"code":"SSZJPZ","label":"IBM InfoSphere Information Server"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"--","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"}],"Version":"8.5;8.1;8.0;7.5","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
16 June 2018

UID