Troubleshooting
Problem
Attempts to profile a 32 bit IBM WebSphere Application Server application using JRE 1.4 on an AIX 64 bit POWER PC platform results in failure because the wrong version of Rational Agent Controller was installed due to unclear documentation.
Symptom
Attempts to profile a WebSphere application on 32 bit WebSphere Application Server with JRE 1.4 on AIX 64-bit platform from Rational Application Developer for WebSphere Software results in failures with Rational Agent Controller.
- Rational Agent Controller 8.2.2 was installed on AIX 64 bit by following the installation instructions for a 64 bit version of AIX located in the download document IBM Rational Agent Controller, Version 8.2.2.
- WebSphere Application Server v6.0.2.x JVM: -XrunpiAgent:server=enabled (as appropriate for JVM 1.4 or lower)
- LIBPATH environment variable was set to point to the <rac_install>/lib directory (where <rac_install> is /opt/IBM/SDP/AgentController.)
- Start-up of WebSphere Application Server 6.0 with the above environment variables set, resulted in the following error:
No java stack
JVMCI158: Can't load "libpiAgent.a", because load ENOENT on shared
library(s)
JVMCI098: xmloadJVMHelperLib piAgent server=enabled, failed
Could not create the Java virtual machine.
[{"Product":{"code":"SSRTLW","label":"Rational Application Developer for WebSphere Software"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Component":"Profiling \/ Performance Analysis","Platform":[{"code":"PF033","label":"Windows"},{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"}],"Version":"7.5.5.1;7.5.5;7.5.4;7.5.3;7.5.1;7.5","Edition":"","Line of Business":{"code":"LOB77","label":"Automation Platform"}}]
Log InLog in to view more of this document
This document has the abstract of a technical article that is available to authorized users once you have logged on. Please use Log in button above to access the full document. After log in, if you do not have the right authorization for this document, there will be instructions on what to do next.
Was this topic helpful?
Document Information
Modified date:
16 June 2018
UID