Troubleshooting
Problem
Error code 0x9000028C for Generic Control Facility (GCF) is logged in the db2diag.log
Symptom
An error similar to the one below is found in the db2diag.log:
2010-06-17-00.01.42.260255-240 I12757178C260 LEVEL: Error
PID : 2351188 TID : 1
FUNCTION: DB2 Common, Generic Control Facility, GcfCaller::getState, probe:40
MESSAGE : ECF=0x9000028C Timeout occured while calling a GCF interface function
The actual db2diag.log entry format will vary depending on the DB2 version, but the key tokens are "GcfCaller::getState, probe:40" and the error code 0x9000028C.
This has no apparent impact on the database, and the error is not reported to the front end.
Log InLog in to view more of this document
Was this topic helpful?
Document Information
Modified date:
30 April 2025
UID