Abstract

OSP-DB-MSGMCH3601-F/QSQRUND PREVENT RECURSIVE LOOP DURING ENDJOB

Error Description

Prevent recursive looping between QSQFCI exception handler path
and QSQSETTXT.  QSQFCI calls ?SQSETTXT and QSQSETTXT calls      
?SQFCONDI.  Since we are in job termination, some MCH3601's are
expected and should be ignored, but it shouldn't result in      
looping.                                                        
                                                               
Fix here is to first check SQLCOND@ is NULL and if so, do not  
process further.  That will prevent some MCH3601's.  The second
change is to create a new STATIC ABNORMAL bit in QSQFCI and set
it once we enter the exception handler path so that we do not  
recursively call between QSQSETTXT and QSQFCI under MCH3601    
exceptions.                                                    

Problem Summary

****************************************************************
* PROBLEM: (SE55247) Licensed Program = 5770SS1                *
*           Crash/Hang Requiring an IPL to Recover             *
*            SRC B600 5121                                     *
*           Looping Condition                                  *
****************************************************************
* USERS AFFECTED: All IBM i operating system users.            *
****************************************************************
* RECOMMENDATION: Apply PTF SI49756 for IBM i 7.1.             *
****************************************************************
Recursive looping between QSQFCI exception handler path and    
QSQSETTXT when in job termination due to ENDJOB.                

Problem Conclusion

Prevent recursive looping between QSQFCI and QSQSETTXT during  
job termination.                                                

Temporary Fix

                       *********                                
                       * HIPER *                                
                       *********                                

Comments

Circumvention


ENDJOBABN should end recursive job.                            

PTFs Available

R710 SI49756 PTF Cover Letter   3298

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5770SS1DB
Failing Module.......................... RCHMGR
Reported Release................... R710
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG16C","label":"APARs - IBM i 7.1 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
16 November 2013