Troubleshooting
Problem
This technote identifies an error, More than one version with label of type, that can occur in IBM Rational ClearCase due to a defect that causes multiple versions of the same element to be labeled unexpectedly.
Symptom
When browsing a UCM directory within a component from a stream, the ClearCase Explorer crashes with the error:
Windows - Fatal Application Exit
mvfs: error in the configuration specification for view myview_int see the vobrpc_server_log on host
myhost for details.
Also creating baselines or upgrading existing baselines to fully labeled (cleartool chbl -full) fail with the error:
"More than one version with label of type "mybaseline" "
When inspecting the vobrpc_server_log after trying to access the directory it shows:
"More than one version with label of type "mybaseline" "
After modifying or creating baselines, the following error is logged in the db_server log:
db_vista_error -3 (errno=="Resource temporarily unavailable")
DBMS error in /vobstore/myvob.vbs/db
DBMS error in "../db__label.c" line 71
Log InLog in to view more of this document
Was this topic helpful?
Document Information
Modified date:
23 June 2018
UID
swg21402608