IBM Support

TR1102 Transformer Server detected an error in line nn in file

Troubleshooting


Problem

Error TR1102 Transformer Server detected an error in line nn in file A level specified by name or unique id was not found after restoring, synchronizing or attempting to open a model.

Resolving The Problem

1. Save the .pyg file from the client as an .mdl file and try reopening the .mdl file. If you obtain an error at a specific line number, open the mdl file in a text editor and verify that you do not have 'strange' ASCII characters at the specified line number. If you do this could indicate a corrupt model.

2. If using Oracle, confirm that the version of SQL*Net being used is 2.x. Also confirm that there is a TNSNames.ora file present on the pc. (If the previous version of SQL*Net is being used this file will not be present.) Version 1x of SQL*Net is unsupported by Oracle and will not interact successfully with Transformer.

[{"Product":{"code":"SSTQPQ","label":"Cognos Series 7"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"PowerPlay","Platform":[{"code":"PF025","label":"Platform Independent"},{"code":"PF033","label":"Windows"}],"Version":"PowerPlay Client 5.0;PowerPlay Client 5.21;PowerPlay Transformer 5.2;PowerPlay Transformer 5.21;PowerPlay Transformer 7.1;PowerPlay Transformer 7.3","Edition":"","Line of Business":{"code":"","label":""}},{"Product":{"code":"SSTQPQ","label":"Cognos Series 7"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Transformer","Platform":[{"code":"","label":""}],"Version":"","Edition":"","Line of Business":{"code":"","label":""}}]

Historical Number

59079

Document Information

Modified date:
15 June 2018

UID

swg21352492