General Page
If the GMCV or GMIR switch causes the partnership to stop and brings down the auxiliary cluster when it tries to restart the RCCG, and the log has these entries:
SVC command [svctask stoprcconsistgrp 2] (qzrdSPPRC gmirFailOver)
State = consistent_stopped (waitForStateChange)
SVC command [svctask chrcconsistgrp -cyclingmode none 2] (qzrdSPPRC gmirFailOver)
SVC command [svctask startrcconsistgrp -force 2]
Error SSH session reported error : command [svctask startrcconsistgrp -force 2] : result [exit-sta
Error Error starting RCCG : (gmirFailOver V7k)
This is a bug in the cluster firmware vesion 7.5.0.2 (and maybe earlier). The fix is to apply 7.5.0.3 or newer to both clusters.