How To
Summary
Demonstration of the steps to use the Microcode Discovery Service for your VIO Server
Objective
Use the IBM Microcode Discovery Service to check the system and IO adapter microcode on a Virtual IO Server.
Environment
IBM PowerVM VIOS
Steps
- Visit the Microcode Discovery Service and download the latest catalog.mic
- From the Microcode Discovery Service site https://esupport.ibm.com/customercare/mds
- Select "Running Inventory Scout"
- Then, look for "The most current microcode catalog can be found [/] here."
- Right-Click on the link at the end of the sentence and select "Save link as".
- Copy the catalog.mic to the padmin users home directory on the VIO
- Replace the existing catalog.mic
$ oem_setup_env
# cp /var/adm/invscout/microcode/catalog.mic /var/adm/invscout/microcode/catalog.mic.orig
# mv /home/padmin/catalog.mic /var/adm/invscout/microcode/catalog.mic
# chmod 644 /var/adm/invscout/microcode/catalog.mic
# chown root:system /var/adm/invscout/microcode/catalog.mic
# exit
- Run Inventory Scout tool as padmin on the VIOS
$ invscout -report
Upload the resulting <hostname>.mup file from the padmin users home directory to the MDS Upload service
- Microcode Discovery Service Manual file upload
- https://esupport.ibm.com/customercare/mds/fetch?page=upload.jsp
Document Location
Worldwide
[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPHKW","label":"PowerVM Virtual I\/O Server"},"ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Versions"}]