Troubleshooting
Problem
This document describes how to correct a 'not authorized' message to the user's output queue.
Resolving The Problem
I am trying to work with output queues and spooled files. Why do I get message CPF2207 - User Profile Not Authorized to Object when *PUBLIC has all object authority?
Check the AUTCHK parameter of the output queue (CHGOUTQ). If this parameter is set to *OWNER, only the owner of the output queue or a user with *SPLCTL can make these changes. To allow others to perform these operations, the AUTCHK parameter must be set to *DTAAUT, and the user must have *READ, *ADD, and *DLT authorities to the object.
Reference: Security Reference manual Appendix D.
Check the AUTCHK parameter of the output queue (CHGOUTQ). If this parameter is set to *OWNER, only the owner of the output queue or a user with *SPLCTL can make these changes. To allow others to perform these operations, the AUTCHK parameter must be set to *DTAAUT, and the user must have *READ, *ADD, and *DLT authorities to the object.
Reference: Security Reference manual Appendix D.
[{"Type":"MASTER","Line of Business":{"code":"LOB68","label":"Power HW"},"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SWG60","label":"IBM i"},"ARM Category":[{"code":"a8m0z0000000CHyAAM","label":"Security"}],"ARM Case Number":"","Platform":[{"code":"PF012","label":"IBM i"}],"Version":"All Versions"}]
Historical Number
9434442
Was this topic helpful?
Document Information
More support for:
IBM i
Component:
Security
Software version:
All Versions
Operating system(s):
IBM i
Document number:
682945
Modified date:
04 October 2024
UID
nas8N1010055
Manage My Notification Subscriptions